TROUBLESHOOTING
When encountering an issue with the Showstopper Remote the first thing to check would be to make
sure that all cables are properly plugged into their respective receivers. Once that has been checked,
the next step would be to make sure that power is turned on. If power is turned on and all cables are
connected properly then it would be best to make sure no emergency stop button in the system is
engaged.
COMMON PROBLEMS
The issue that is most often encountered is having an open termination somewhere in the system.
The Accessory inputs and outputs must always be terminated. At the Showstopper Base there are
three Accessory outputs, there should be a cable or terminator plugged into them for the system to
transmit power. Similarly, all remotes in the system should be terminated at the output if it is the last
remote in the system or have a cable plugged into both the input and output ports. If you see any
Accessory input or output port with nothing plugged into it, the system will not run.
Indicator
Check Power
Local E-Stop
Engaged
Another E-Stop
Engaged
Ready to Make It
Move!
Ready
-
-
-
X
Engaged
-
X
-
-
None
X
X