Smartwasher
SW-37
Operating Manual
|
10
Trouble Shooting Continued
CHECKING for Problems: Issue -
EXCESSIVE FLUID LOSS:
1.
Check the fluid temperature, If the temperature is above 49°C
the probe is not working properly. Temperatures above 49°C will
increase the rate of evaporation.. Please turn machine off at
the wall and unplug. Then contact CRC NZ on 09 272 27 00 for
technical assistance.
2.
Examine closely where the sink and base meet. Are there any
gaps? Is the base bowed? Is the sink warped? The
SmartWasher
®
operates as a closed system; any gaps will
provide space for air to enter and condensation to escape.
3.
Is the SmartWasher
®
“leaking”? Where is it “leaking” from?
Make sure the nozzle and brush are flowing into the sink. If the
fluid is leaking from the body of the base? The base will need to
be replaced.
4.
If none of the previous apply, this rules out any problem with the
SmartWasher
®
itself. Make sure you and your co-workers are
aware that certain practices can cause you to use excessive
amounts of OzzyJuice
®
. Refer to “Checking Practices” section
on this page.
ISSUE - Low or No Fluid from Brush/Nozzle
Check the following:
1.
Make sure that the valves at the base of the nozzle and brush
are open. If a stronger flow through either device is needed,
turn the valve on the unused tool to the closed position.
2.
Hoses from the pump to the nozzle and brush could be
clogged, pinched or disconnected. Check the hoses from the
pump to the nozzle making sure they are in working order.
3.
Make sure SmartWasher
®
is not low on fluid.
4.
Hose connections should be secure and not leaking.
5.
The pump comes with a two year factory warranty. If the pump
is faulty, call CRC Technical Support on 09 272 2700 to order
your warranty replacement. Have the serial number of the
SmartWasher
®
unit available when calling.
CHECKING Practices:
•
How often, how much and when are you adding fluid?
A full 20L container of OzzyJuice
®
should be added immediately
when the “Add Fluid Light” comes on. The system is designed to
warn users at the point at which fluid should be added. Please
keep in mind that the light will remain illuminated while fluid
is low, and more fluid will be needed to reach the proper
operating level.
•
When did you notice the change in usage?
If fluid usage has been fine for a period of time and usage has
just recently increased, check to see if anything has changed
recently. (New employees, more employees, more parts being
cleaned, longer hours of use, etc.)
•
How many hours a day do you have the pump running?
The
more the pump runs, the more evaporation occurs. Never leave
the pump running when the SmartWasher
®
is not in use.
•
How many operators and how many hours a day are you using
the SmartWasher
®
?
This will help you determine if they have high, normal or low
usage. If you have higher than normal usage, you will have
higher fluid usage.
•
Does the OzzyMat
®
clog up and cause the fluid to pool up in
the sink?
If the fluid is backing up in the sink and not draining through the
OzzyMat
®
properly, there will be increased evaporation and the
low fluid light may come on prematurely because the fluid is in
the sink, not in the base. Please refer to FAQ section and read
question “What do I do if the OzzyMat
®
clogs up quickly with
grease?”.
•
Are operators squeezing the excessive fluid out of the
OzzyMat
®
into the sink after installing a new OzzyMat
®
?
When changing out the old OzzyMat
®
, roll up used OzzyMat
®
and stand vertically against the side of the sink to drain
excess fluid..
For technical support visit our website www.crcind.com.au/smartwasher or call us on 1800 224 227