2 r0s0n2 on -62 -67 25 - -62 -1 - - - - 1 -62
3 r0s0n3 on -58 -65 25 - -58 -1 - - - - 1 -58
4 r0s0n4 on -61 -67 25 - -61 -1 - - - - 1 -61
5 r0s0n5 on -61 -66 25 - -61 -1 - - - - 1 -61
6 r0s0n6 on -61 -66 26 - -61 -1 - - - - 1 -61
7 r0s0n7 on -51 -58 26 - -51 -1 - - - - 1 -51
8 r0s0n8 on -63 -65 24 - -63 -1 - - - - 1 -63
9 r0s0n9 on -62 -69 24 - -62 -1 - - - - 1 -62
10 r0s0n10 on -60 -67 25 - -60 -1 - - - - 1 -60
11 r0s0n11 on -59 -63 26 - -60 -1 - - - - 1 -60
12 r0s0n12 on -62 -66 25 - -62 -1 - - - - 1 -62
13 r0s0n13 on -61 -67 25 - -61 -1 - - - - 1 -61
14 r0s0n14 on -59 -68 25 - -59 -1 - - - - 1 -59
15 r0s0n15 on -58 -66 25 - -58 -1 - - - - 1 -58
ok
[r0s0i0 /]#
sensor 4
id: 4
slot: 4
name: r0s0n4
present: on
power: on
sensors: 4
status: ok
p1_margin: ok ( -60.0 'C)
p2_margin: ok ( -68.0 'C)
inlet: ok ( 25.0 'C)
outlet: disabled
delta: ( -1 'C)
node_margin: ( -60 'C)
ok
[r0s0i0 /]#
set
Display or set iSCB parameters
Syntax:
set <param> [value]
Parameters:
ace [on|off]
Support ACE cluster. Not implemented for Urika-GX.
Default is off.
acelog [level]
If ace is set, generate ace related log of defined level: info,
warning, critical
activefan [on|
off]
Dynamic Fan Control by node’s health status. The each
CFU will run at low, normal and high speed by where
located node’s temperature. If it is off, entire CFU will run at
default fan speed. This setting is override by IDSW1-7.
Default is on.
authkey
[auth_key]
Authorized key into
/root/.ssh/authorized_key
.
baud [speed]
Remote console speed. Default is 115200.*
blade [type [name
[id]]]
Blade type, name(max 14chars) and ID. Type is one of
auto, GB5XX, GB6XX, GB8XX and GB828.*
checkpsu [on|off]
Check the PSUs. If it is off, the power and energy usage
capability of subrack level will not work. Default is on.*
cputemp [temp]
The reference temperature of CPU. For Intel EPSD
platform, this value is will be used for reference
temperature for marginal bmc sensors. For example, the
System Monitoring
S3016