35
National Rejectors, Inc. GmbH, Buxtehude
c
2
Configuration
c
ash
accepTance
Optimising acceptance of genuine coins/rejection of fraud
coins (defining acceptance tolerances)
For the acceptance of (high-value) coins programmed the coin changer is
capable of having up to three acceptance bands with different acceptance
tolerances. In order that genuine coins are always accepted and fraud
coins rejected reliably you may assign a "normal", "narrow" or "very narrow"
(smallest acceptance tolerances) acceptance band.
Narrow and very narrow acceptance bands possess a lower acceptance
rate of genuine coins.
To select the acceptance tolerances:
Quick approach:
= Main menu > E = Settings > Coin settings > Security level
Press key ...
How often?
effect
1
1 x
You enter the main menu
2
1 x
You enter the
s
eTTinG
menu
3
until
Coin settings
You want to enter submenu
c
oin
seTTinGs
4
1 x
You enter the submenu
5
until
Security level
You want to specify a coin’s
acceptance tolerances
6
1 x
Now you select the coin
7
/
until coin with problematic
acceptance
You want to select a
n
ormal
/
narrow
/
very
narrow
acceptance band for this
coin
8
1 x
Now you can select the acceptance
band
9
/
until acceptance band width
desired
You want the coin to be accepted in
this band width
10
1 x
You lock the setting in memory
11
1 x/2 x
You return to main menu/operating
mode