14
National Rejectors, Inc. GmbH, Buxtehude
c
2
Configuration
s
eTTinGs
for
fillinG
anD
empTyinG
casseTTe
Settings for filling and emptying cassette
4
This chapter describes useful or required settings for refilling and emptying
the coin cassette:
Configuring float level
•
Setting tube counters to float-level automatically
•
Correcting tube counters according to filling level sensors
•
Resetting tube counters before refilling cassette
•
Redirecting cash-box coins to return area
•
Reporting inserted coins to machine (only c
•
2
MDB)
Disabling/enabling inventory keys / disabling/enabling inventory keys
•
using MDB/BDV protocol
Which settings should be done?
To enable the coin changer to register the exact coin number we recommend
the following settings depending on the filling method used:
Settings for tube refilling by coin insertion
If the cassette is refilled by inserting the tube coins (and without emptying
the cassette completely beforehand), see that the tube counters are
not
corrected according to the filling level sensors automatically, as the inserted
coins will be registered exactly in the tube filling mode.
Whereas, if you remove and completely empty the cassette before inserting
the tube coins, you should set the following in order to reset the tube
counters before refilling the cassette:
Resetting the tube counters before refilling the cassette
•
Correcting tube counters according to filling level sensors automatically
•
Settings for direct refilling the removed cassette
If the cassette is removed to be directly refilled with a certain number of coins
per tube, i.e. counted coins, the coin changer must be set as follows to ensure
the exact registration of the coin number:
Configuration of the coin number as float level per tube
•
Automatic tube counter setting to float levels
•
De
•
activation of the automatic tube counter correction according to filling
level sensors
If the cassette is removed to be directly refilled with any number of coins, the tube
counters must be corrected according to filling level sensors automatically.
Содержание NRI Currenza C2