background image

2

Please Read This Before Installing Or Operating 
Pump. This information is provided for 

SAFETY

 and 

to 

PREVENT EQUIPMENT PROBLEMS.

 To help 

recognize this information, observe the following 
symbols:

IMPORTANT!

 Warns about hazards that 

can result in personal injury orIndicates 
factors concerned with assembly, 
installation, operation, or maintenance 
which could result in damage to the 
machine or equipment if ignored.

CAUTION!

 Warns about hazards that 

can or will 

cause minor

 personal injury or property damage if 

ignored. Used with symbols below.

WARNING!

  Warns about hazards that can or 

will cause serious personal injury, death, or major 
property damage if ignored. Used with symbols 
below.

Only qualifi ed personnel should install, operate 
and repair pump. Any wiring of pumps should be 
performed by a qualifi ed electrician.

WARNING!

 To reduce risk of electrical 

shock, pumps and control panels must 
be properly grounded in accordance 
with the National Electric Code (NEC) 
or the Canadian Electrical Code (CEC) 
and all applicable state, province, 
local codes and ordinances. Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical 

shock, always disconnect the pump 
from the power source before handling 
or servicing. Lock out power and tag. 

CAUTION !

 Never operate a pump 

with a plug-in  type power cord without 
a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build 

up heat and pressure 
during operation-allow time 
for pumps to cool before 
handling or servicing.

WARNING!

 Do not pump hazardous 

materials (fl ammable, caustic, etc.) 
unless the pump is specifi cally designed 
and designated to handle them.

CAUTION!

 

Do not

 block or restrict 

discharge hose, as discharge hose may 
whip under pressure.

WARNING!

 Do not wear loose clothing 

that may  become entangled in moving 
parts.

WARNING!

 Keep clear of suction and 

discharge openings. 

DO NOT 

insert 

fi ngers in pump with power connected.  

Always wear eye protection when working 
on pumps. 

Make sure lifting handles are securely 
fastened each  time before lifting. 

DO 

NOT

 operate pump without safety 

devices in place. Always replace safety 
devices that  have been removed during 
service or repair. Secure the pump in its 
operating position so it can not tip over, 
fall  or slide.

DO NOT

 exceed manufacturers 

recommendation for maximum 
performance, as this could cause the 
motor  to overheat.

DO NOT

 remove cord and strain relief. 

DO NOT

 connect conduit to pump.

 

WARNING!

 Cable should be protected 

at all times to  avoid punctures, cut, 
bruises and abrasions. Inspect frequently. 
Never handle connected power cords 
with  wet hands.

 

WARNING!

 To reduce risk of 

electrical shock, all  wiring and junction 
connections should be made per  the 
NEC or CEC and applicable state or 
province and  local codes. Requirements 
may vary depending on  usage and 
location.

 

WARNING!

 Submersible Pumps are 

not approved for  use in swimming pools, 
recreational water installations decorative 
fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING!

 Products returned must be 

cleaned, sanitized, or decontaminated 
as necessary prior to shipment, to insure 
that employees will not be exposed to 
health hazards in handling said material. 
All Applicable Laws And Regulations 
Shall Apply.

Bronze/brass and bronze/brass fi tted 
pumps may contain lead levels higher 
than considered safe for potable water 
systems. Lead is known to cause cancer 
and birth defects or other reproductive 
harm. Various government agencies 
have determined that leaded copper 
alloys should not be used in  potable 
water applications. For non-leaded 
copper  alloy materials of construction, 
please contact factory.

Crane Pumps & Systems, Inc. is not 
responsible for losses, injury, or death 
resulting from a failure to observe these 
safety precautions, misuse or abuse of 
pumps or equipment.

GENERAL INFORMATION:

To The Purchaser - 

Congratulations! You are the 

owner of one of the fi nest pumps on the market 
today. Barnes® Pumps are products engineered 
and manufactured of high quality components. Over 
one hundred years of pump building experience 
along with a continuing quality assurance program 
combine to produce a pump which will stand up to 
the toughest applications.

The pump is packaged ready for installation and no 
connections or adjustments are necessary except 
for attaching a standard 3/4 inch NPT garden hose 
to the discharge and plugging in service cord.

Receiving - 

Upon receiving the pump, it should be 

inspected for damage or shortages. If damage has 
occurred, fi le a claim immediately with the company 
that delivered the pump. If the manual is removed 
from the crating, do not lose or misplace.

Storage:
Short Term-

 Barnes Pumps are manufactured for 

effi cient performance following long inoperative 
periods in storage. For best results, pumps can be 
retained in storage, as factory assembled, in a dry 
atmosphere with constant temperatures for up to six 
(6) months.

Long Term-

 Any length of time exceeding six (6) 

months, but not more than twenty four (24) months. 
The units should be stored in a temperature 
controlled area, a roofed over walled enclosure that 
provides protection from the elements (rain, snow, 
wind blown dust, etc..), and whose temperature can 
be maintained b40 deg. F and +120 deg. 
F. Pump should be stored in its original shipping 
container and before initial start up, rotate impeller 
by hand to assure seal and impeller rotate freely.

Service Centers - 

For the location of the nearest 

Barnes Service Center, check your catalog, 
your Barnes representative or Barnes Service 
Department in Piqua, Ohio, telephone (937) 778-
8947, in Bramton, Ontario, Canada, (905) 457-6223 
or www.cranepumps.com.

INSTALLATION:

Location - 

This product is designed to pump water 

only and is 

NOT

 recommended for use in a sump 

or basin. Product failures due to pumping mud, tar, 
cement, wood chips, or damage from corrosive 
materials are 

NOT 

covered under the manufacturing 

warranty and will not be accepted as a return. Never 
install the pump in a trench, ditch, or hole with a dirt 
bottom where the suction will become plugged.

This unit shall 

NOT

 be installed in locations 

classifi ed as hazardous in accordance with the 
National Electrical Code (NEC), ANSI/NFPA 70 or 
the Canadian Electrical Code (CEC). 

Submergence - 

The minimum liquid level should 

never be less than 1/8 inch (3.2mm) above the 
pump bottom. Unplug this unit when water has 
drained to 1/8 inch (3.2mm).

Discharge - 

Discharge hose should be as short 

as possible. The installation of a check valve in the 
discharge piping is recommended for each pump 
being used. The check valve is used to prevent 
backfl ow into the sump.

SAFETY FIRST!

Hazardous fl uids can cause fi re or ex-
plosions, burnes or death could result.

Extremely hot - Severe burnes can 
occur on contact.

Biohazard can cause serious personal 
injury.

Hazardous fl uids can Hazardous 

pressure, eruptions or explosions could 
cause personal injury or  property damage.

Rotating machinery
Amputation or severe laceration can 
result.

Hazardous voltage can shock, burn or 
cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems, Inc.
 

2002, 

8/2004, 

5/06, 

9/06, 

3/07        Alteration 

Rights 

Reserved

Содержание BARNES UT17

Страница 1: ...457 2650 www cranepumps com Form No 113829 Rev F SPECIFICATIONS DISCHARGE 3 4 G H T Male Vertical LIQUID TEMPERATURE 77 F 25 C Continuous MOTOR HOUSING Thermoplastic PUMP STRAINER Thermoplastic IMPELLER 2 Vane Semi Open Thermoplastic SHAFT Steel O RINGS Buna N HARDWARE Stainless Steel CABLE ENTRY 15 Ft 4 5M Cord with Plug and Pressure Grommet for Sealing and Strain Relief CABLE TYPE 18 3 SJTW SEAL...

Страница 2: ...ould not be used in potable water applications For non leaded copper alloy materials of construction please contact factory Crane Pumps Systems Inc is not responsible for losses injury or death resulting from a failure to observe these safety precautions misuse or abuse of pumps or equipment GENERAL INFORMATION To The Purchaser Congratulations You are the owner of one of the finest pumps on the ma...

Страница 3: ...nd start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SERVICE AND REPAIR Strainer Remove screws and remove strainer from volute and remove volute Clean and examine impeller If impeller vanes are clogged or it is excessiv...

Страница 4: ...formance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATI...

Страница 5: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 6: ...Notes ...

Отзывы: