background image

2

Please  Read  This  Before  Installing  Or  Operating  Pump. 
This  information  is  provided  for 

SAFETY

  and  to 

PREVENT 

EQUIPMENT  PROBLEMS.

  To  help  recognize  this  information, 

observe the following symbols:

IMPORTANT!

  Warns  about  hazards  that  can  result 

in  personal  injury  orIndicates  factors  concerned  with 
assembly,  installation,  operation,  or  maintenance  which 
could  result  in  damage  to  the  machine  or  equipment  if 
ignored.

CAUTION!

  Warns  about  hazards  that 

can  or  will  cause  minor

 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only  qualifi ed  personnel  should  install,  operate  and  repair 
pump. Any  wiring  of  pumps  should  be  performed  by  a  qualifi ed 
electrician.

WARNING  !

  To  reduce  risk  of  electrical  shock,  pumps 

and  control  panels  must  be  properly  grounded  in 
accordance  with  the  National  Electric  Code  (NEC)  or 
the  Canadian  Electrical  Code  (CEC)  and  all  applicable 
state,  province,  local  codes  and  ordinances.  Improper 
grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

 

CAUTION !

 

Do not

 block or restrict discharge hose, as 

discharge hose may whip under pressure.

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert fi ngers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make  sure  lifting  handles  are  securely  fastened  each  
time before lifting. 

DO NOT

 operate pump without safety 

devices  in  place.  Always  replace  safety  devices  that  
have been removed during service or repair. Secure the 
pump in its operating position so it can not tip over, fall  
or slide.

 

DO  NOT

  exceed  manufacturers  recommendation  for 

maximum  performance,  as  this  could  cause  the  motor  
to overheat.

 

DO NOT

 remove cord and strain relief. 

DO NOT

 connect 

conduit to pump.

 

WARNING  !

  Cable  should  be  protected  at  all  times  to  

avoid  punctures,  cut,  bruises  and  abrasions.  Inspect 
frequently.  Never  handle  connected  power  cords  with  
wet hands.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 
or  CEC  and  applicable  state  or  province  and    local 
codes.  Requirements  may  vary  depending  on    usage 
and location.

 

WARNING!

  Submersible  Pumps  are  not  approved  for  

use  in  swimming  pools,  recreational  water  installations 
decorative  fountains  or  any  installation  where  human 
contact with the pumped fl uid is common.

  

WARNING!

  Products  returned  must  be  cleaned, 

sanitized,  or  decontaminated  as  necessary  prior  to 
shipment, to insure that employees will not be exposed 
to health hazards in handling said material. All Applicable 
Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in  potable water 
applications. For non-leaded copper  alloy materials of 
construction, please contact factory.

 

Crane  Pumps  &  Systems,  Inc.  is  not  responsible  for 
losses, injury, or death resulting from a failure to observe 
these safety precautions, misuse or abuse of pumps or 
equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems, Inc.
 2002, 2003, 6/2004, 5/06, 9/06 

 

 

 

 

 

 

 

Alteration Rights Reserved

Содержание BARNES SP33 Series

Страница 1: ...roduct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 112251 Rev P Series SP33 33 HP 3450 RPM 60 Hz 2 HP 2850 RPM 50 Hz ...

Страница 2: ...ake sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT rem...

Страница 3: ...ARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design Oil Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC ELECTRICAL 120 Volt 1 Phase 60 Hz 5 8FLA 50 Hz 5 0FLA WINDING RESISTANCE Main 4 3 Ω Start 12 7Ω LEVEL CONTROLS SP33 None SP33A Wide Angle Mechanical 10 Ft 3m Cord or 20 Ft 6m Cord SP33V V...

Страница 4: ...arnes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recom mended for use in a sump or basin This pump is designed to pump rain water or light effluent nonexplosive and noncorrosive liquids and shall NOT ...

Страница 5: ...t the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SECTION D SERVICE AND REPAIR ...

Страница 6: ...ge and pump design This number is used for ordering and obtain ing information E 3 Date Code The Date Code consists of two numbers which are punched holes in the nameplate This specifies the month and year which indicates the date the unit was built SERVICE PARTS AVAILABLE LEVEL CONTROLS 113647 Vertical Float 10 Ft Piggy Back 113647A Vertical Float 20 Ft Piggy Back 106929 Mech Wide Angle 10 Ft Pigg...

Страница 7: ...heck cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fl...

Страница 8: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS ...

Страница 9: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 10: ...Notes ...