![Crane Barnes SGVF Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/crane/barnes-sgvf-series/barnes-sgvf-series_installation-manual_2679192005.webp)
5
MODEL
NO
PUMP
WEIGHT
lbs (kg)
HP
(kW)
VOLT
PH/Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CODE
TYPE
CORD
O.D.
± .02 (.5)
in (mm)
WINDING
RESISTANCE
MAIN -- START
SGV*2002L 100 (45.4)
2
200
1 / 60
3450
F
17.0
53.0
12/4
SOW
.67 (17)
0.9 -- 7.2
SGV*2022L 100 (45.4)
2
240
1 / 60
3450
H
15.0
53.8
12/4
SOW
.67 (17)
1.5 -- 5.1
SGV*2062L 100 (45.4)
2
200
3 / 60
3450
J
11.0
42.0
12/4
SOW
.67 (17)
2.4
SGV*2032L 100 (45.4)
2
240
3 / 60
3450
J
9.0
36.0
12/4
SOW
.67 (17)
3.1
SGV*2042L 100 (45.4)
2
480
3 / 60
3450
J
4.0
18.0
12/4
SOW
.67 (17)
12.4
SGV*2052L 100 (45.4)
2
600
3 / 60
3450
J
3.2
14.4
12/4
SOW
.67 (17)
16.1
SGV*20Z2L 100 (45.4) 1.1 (.9) 380-415
3 / 50
2850
G
3.3
15.0
12/4
SOW
.67 (17)
12.4
Winding Resistance ± 5%, measured from terminal block. Pump rated for operation at ± 10% voltage at motor.
Optional
- Temperature sensor cable for all models is 14/3 SOW, 0.55 ± .02 O.D. (Not used on SGV2022L).
Optional
- Moisture and Temperature sensor cable for all models is 18/5 SOW, 0.49 ± .02 O.D., replaces Temperature sensor cable.
Recommended Breaker & Heater Sizes
Pump Model
HP
Phase
Volts
Breaker Size
Heater Size
Voltage Relay
Start Capacitor
Run Capacitor
SGV*2002L
2
1
200
30 AMP
K-60
MARS 67
143 mfd - 220 volts
20 mfd - 370 volts
SGV*2022L
2
1
240
30 AMP
K-57
MARS 68
143 mfd - 220 volts
45 mfd - 450 volts
SGV*2062L
2
3
200
20 AMP
K-53
N/R
N/R
N/R
SGV*2032L
2
3
240
20 AMP
K-50
N/R
N/R
N/R
SGV*2042L
2
3
480
15 AMP
K-33
N/R
N/R
N/R
SGV*2052L
2
3
600
15 AMP
K-31
N/R
N/R
N/R
SGV*20Z2L
1.1
3
380-415
15 AMP
K-31
N/R
N/R
N/R
NOTE: Factory recommended heater sizes may vary depending on pump station requirements.
N/R = Not Required.
(*) = F for High-Flow or H for High-Head.