background image

17

A Crane Co. Company

420 Third Street 

83 West Drive, Brampton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Limited 24 Month Warranty

Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship 
under  normal  use  and  service  for  twenty-four  (24)  months  after  manufacture  date,  when  installed  and  maintained 
in  accordance  with  our  instructions.This  warranty  gives  you  speci

fi c  legal  rights,  and  there  may  also  be  other  rights 

which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law 
(1)  the  duration  of  any  implied  warranties  associated  with  the  product  by  virtue  of  said  law  is  limited  to  the  same 
duration  as  stated  herein,  (2)  this  warranty  is  a  LIMITED  WARRANTY,  and  (3)  no  claims  of  any  nature  whatsoever 
shall  be  made  against  us,  until  the  ultimate  consumer,  his  successor,  or  assigns,  notifi es  us  in  writing  of  the  defect, 
and  delivers  the  product  and/or  defective  part(s)  freight  prepaid  to  our  factory  or  nearest  authorized  service  station. 
Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  so  the  above  limitation  may  not  apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY 
PRODUCT  SHALL  BE  TO  REPLACE  OR  REPAIR  AT  OUR  ELECTION,  F.O.B.  POINT  OF  MANUFACTURE  OR 
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE 
NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly 

stated otherwise, guarantees in the nature of performance specifi cations furnished in addition to the foregoing material 
and  workmanship  warranties  on  a  product  manufactured  by  us,  if  any,  are  subject  to  laboratory  tests  corrected  for 
fi eld performance. Any additional guarantees, in the nature of performance specifi cations must be in writing and such 
writing must be signed by our authorized representative. Due to inaccuracies in fi eld testing if a confl ict arises between 
the  results  of  fi eld  testing  conducted  by  or  for  user,  and  laboratory  tests  corrected  for  fi eld  performance,  the  latter 
shall  control. 

RECOMMENDATIONS  FOR  SPECIAL  APPLICATIONS  OR  THOSE  RESULTING  FROM  SYSTEMS 

ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND 
PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF 
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This  warranty  shall  not  apply  when  damage  is  caused  by  (a)  improper  installation,  (b)  improper  voltage  (c)  lightning 
(d) excessive sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any 
modifi cation of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor 
cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without 
our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice 
and\or  our  specifi c  recommendations.  The  purchaser  is  responsible  for  communication  of  all  necessary  information 
regarding the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR 

ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, 
RENTED  EQUIPMENT,  OUTSIDE  CONTRACTOR  FEES,  UNAUTHORIZED  REPAIR  SHOP  EXPENSES,  LOST 
PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES 
ARE  CAUSED  BY  ANY  DEFECTS  IN  MATERIAL  AND\OR  WORKMANSHIP  AND\OR  DAMAGE  OR  DELAYS  IN 
SHIPMENT.  THIS  WARRANTY  IS  EXPRESSLY  IN  LIEU  OF  ANY  OTHER  EXPRESS  OR  IMPLIED  WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, 
without our prior written approval.

Содержание Barnes SED Series

Страница 1: ...ms Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 105240DW Rev A Series SED 50HP 1750RPM ...

Страница 2: ... SHOOTING 13 EXPLODED VIEW Fig 14 14 PARTS LIST 15 WARRANTY 16 RETURNED GOODS POLICY 17 WARRANTY REGISTRATION 17 SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT see parts list PRESSURE GAUGE KIT see parts list Other brand and product names are trademarks or registered trademarks of their respective holders BARNES is a registered trademark of Crane Pumps Systems...

Страница 3: ... fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers reco...

Страница 4: ...CORD ENTRY 30 ft 9 1m Cord with Plug on Single Phase Quick connect custom molded for sealing and strain relief SPEED 1750 RPM Nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design NEMA L Single Phase NEMA B Three Phase Torque Curve Oil Filled Squirrel Cage Induction Insulation Class B SINGLE PHASE...

Страница 5: ... telephone 937 778 8947 or Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location Water feeding and discharging for construction and civil works Water supply and sewage works Various kinds of industrial facilities Housing and building facilities The pump can be used at almost all places but avoid continuous short water operation at a sandy place such may ac...

Страница 6: ...termediate control circuit relay must be used to reduce the current or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 440 480 0 75 7 5 C 3 3 Wire Size Consult a qualified electrician for proper wire size if additional power cable length is required See table for electrical information SECTION D STAR...

Страница 7: ...l and contamination F 1 1 Checking Oil Motor Housing To check oil set unit upright Remove pipe plug 15 from motor housing 1 With a flashlight visually inspect the oil in the motor housing 1 to make sure it is clean clear light amber in color and free from suspended particles Milky white oil indicates the presence of water Oil level should be above motor when pump is in vertical position F 1 2 Testi...

Страница 8: ... stationary Apply thread locking compound 60 to shaft threads Then install jam nut 32 and torque to 40 ft lbs It is important that the spring of the lower shaft seal 3 seats in the hub of the impeller 33 Rotate impeller to check for binding Position gasket 20 on volute flange and position impeller and motor housing on volute 1 Position lockwasher 12 on cap screw 26 and screw into volute 1 Torque to...

Страница 9: ...f the housing 1 using a T bolt or pair of pliers and a 25 20 screw in the threads of the terminal block 21 Be sure to leave slack on the motor leads connected underneath Use needle nose pliers to pull each female connector off of the pins on the underside of the terminal block 35 The unit voltage should be noted Repeat cable and terminal block removal procedure for any control cables 56 if equippe...

Страница 10: ...ed Do not use wire nuts Slip motor leads and ground wire through fiberglass sleeve Lower motor housing 6 down onto seal plate 5 while aligning holes and stringing motor leads through the cable entry bore s Slipping cords inside a 1 ft length of 5 conduit makes this easier Place socket head cap screws 47 through seal plate 5 into motor housing 1 and torque to 60 in lbs Reconnect motor leads to the u...

Страница 11: ...the design configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific...

Страница 12: ...12 FIGURE 12 ...

Страница 13: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures a...

Страница 14: ...14 FIGURE 13 Series SED ...

Страница 15: ... 25 Dia Cast Iron 15 1 014270 Plug Pipe Countersunk 375 ZP 16 1 017414 Bearing Ball 203 1 5747 OD 17 1 061143 Ring Retaining Ext Steel 18 1 027269 ª Ring Square 264 7 50 ID Buna N 19 6 1 140 1 Screw HXHD 313 18 2 00 SS 20 1 027344 ª Gasket 9 25 OD 21 1 103503 Handle Lifting SS 22 1 Nameplate SS 23 1 Warning Nameplate SS 24 1 Warning Label 25 8 001628 Screw U Drive 4 187 300 SS 26 1 043420 Casting ...

Страница 16: ... ITEMS 16 240 VOLT 1 PHASE 0 5HP ITEM 16 3 PHASE 8 FT 103756A 103742A 15 FT 103756 110949 103742 20 FT 103756XA 110949XA 103742XA 30 FT STD 103756XC 110949XC 103742XC 50 FT 103756XF 110949XF 103742XF 75 FT 103756XJ 110949XJ 103742XJ 100 FT 103756XL 110949XL 103742XL ...

Страница 17: ...performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATION...

Страница 18: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Отзывы: