Please Read This Before Installing Or Operating Pump. 

This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 

assembly, installation, operation, or maintenance which 

could result in damage to the machine or equipment if 

ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 

below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 

with symbols below.

Only  qualified  personnel  should  install,  operate  and  repair 

pump. Any  wiring  of  pumps  should  be  performed  by  a  qualified 

electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 

accordance with the National Electric Code (NEC) or the 

Canadian Electrical Code (CEC) and all applicable state, 

province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 

handling or servicing. Lock out power and tag.

Prevent large articles of clothing, large amounts of chemicals, 

other materials or substances such as are uncommon in domestic 

sewage from entering the system.

During power black-outs, minimize water consumption at the 

home(s) to prevent sewage from backing up into the house.

Always keep the shut-off valve completely open when system is 

in operation (unless advised otherwise by the proper authorities). 

Before removing the pump from the basin, be sure to close the 

shut-off valve. (This prevents backflow from the pressure sewer.)

Keep the control panel locked or confined to prevent unauthorized 

access to it.

If the pump is idle for long periods of time, it is advisable to start the 

pump occasionally by adding water to the basin.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 

before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(flammable, caustic, etc.) unless the pump is specifically 

designed and designated to handle them.

Do not block or restrict discharge hose, as discharge hose may 

whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings.  DO  NOT  insert  fingers  in  pump  with  power 

connected.

Make sure lifting handles are securely fastened each time before 

lifting. Do not operate pump without safety devices in place. 

Always replace safety devices that have been removed during 

service or repair.

Do not exceed manufacturers recommendation for maximum 

performance, as this could cause the motor to overheat.

Secure the pump in its operating position so it can not tip over, 

fall or slide.

Cable should be protected at all times to avoid punctures, cut, 

bruises and abrasions - inspect frequently. 

Never handle connected power cords with wet hands.

To reduce risk of electrical shock, all wiring and junction 

connections should be made per the NEC or CEC 

and applicable state or province and local codes. 

Requirements may vary depending on usage and 

location.

Submersible Pumps are not approved for use in 

swimming pools, recreational water installations, 

decorative fountains or any installation where human 

contact with the pumped fluid is common.

Do not remove cord and strain relief. Do not connect conduit to 

pump. 

Products Returned Must Be Cleaned, Sanitized, Or 

Decontaminated As Necessary Prior To Shipment, To 

Insure That Employees Will Not Be Exposed To Health 

Hazards In Handling Said Material. All Applicable Laws 

And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fitted pumps may contain 

lead levels higher than considered safe for potable water 

systems. Lead is known to cause cancer and birth 

defects or other reproductive harm. Various government 

agencies have determined that leaded copper alloys 

should not be used in potable water applications. For 

non-leaded copper alloy materials of construction, please 

contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 

failure to observe these safety precautions, misuse or 

abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fluids can 

cause fire or explo-

sions, burnes or death 

could result.

Extremely hot - Severe 

burnes can occur on contact.

Biohazard can cause 

serious personal injury.

Hazardous fluids can Hazard-

ous pressure, eruptions or ex-

plosions could cause personal 

injury or property damage.

Rotating machinery

Amputation or severe 

laceration can result.

Hazardous voltage can 

shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.

® Barnes is a registered trademark of Crane Pumps & Systems, Inc

© Crane Pumps & Systems, Inc. 2000, 2003, 5/04, 8/04, 12/05, 1/06   

 

 

 

Alteration Rights Reserved

Содержание Barneb PS SGPC Series

Страница 1: ...ement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 108093 Rev P TM ultra Series SGPC 1 0 HP 1750 RPM 60 Hz SUPERSEDED Some parts may ...

Страница 2: ...G Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this could cause the motor to...

Страница 3: ...is the Barnes UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical ...

Страница 4: ...m 15 Ft 4 6m Std or 30 Ft 9m Cord Custom Molded Quick Connected for sealing and strain relief CORD AU CVP CSA UL Approved 12 5 Type SOW L CSA UL Approved 12 3 Type SOW SPEED 1750 RPM 60Hz UPPER BEARING Design Single Row Ball Lubrication Oil Load Radial LOWER BEARING Design Single Row Ball Lubrication Oil Load Radia Thrust MOTOR Design Oil Filled Squirrel Cage Induction Insulation Class B Type Perm...

Страница 5: ...5 inches mm SGPC1024AUF SGPC1024AUE ESPS 150 Level Control Sold Separatly ...

Страница 6: ...24CVP 1 240 1 D 9 2 17 5 2 3 9 7 PUMP MODEL HP 60Hz BREAKER SIZE CORD SIZE CODE TYPE CORD O D 02 5 in mm CORD LENGHT Ft m SGPC1014L 1 30 AMP 12 3 SOW 61 15 5 15 4 6 SGPC1024L 1 25 AMP 12 3 SOW 61 15 5 15 4 6 SGPC1024AU 1 25 AMP 12 5 SOW 71 18 30 9 SGPC1024AU 1 25 AMP 12 3 SOW 61 15 5 30 9 SGPC1024CVP 1 25 AMP 12 5 SOW 71 18 15 4 6 Winding Resistance 5 measured from terminal block Pump rated for op...

Страница 7: ...he pump be installed and tested before the long term storage begins such installa tion will be allowed provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area SERVICE CENTERS For the location o...

Страница 8: ... float is attached to the piping at the factory or shipped loose Hardware is provided for mounting the ON OFF float typically to a 1 25 NPT pipe Other various mounting methods can be used so long the ON OFF float is 1 Securely mounted to a fixed object such as pipe brackets etc 2 Has a three to three and one half inch tether length 3 Basin wall pump inflow etc DO NOT obstruct float operation 4 Bel...

Страница 9: ...ed to as an inherent overheating protector and operates on the combined effect of temperature and current This means that the overload protector will trip out and shut the pump off if the windings become too hot or the load current becomes too high It will then automatically reset and start the pump after the motor cools to a safe temperature In the event of an overload the source of this conditio...

Страница 10: ...10 FIGURE 5 Single Phase 240 Volt AC with Closed Valve Protection CVP Single phase 240 Volt AC AU Series Wiring Schematic For Pumps with Dual Hole Motor Housing ...

Страница 11: ...ny obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fluid temperature 13 Replace portion of discharge pipe with flexible connector 14 Turn...

Страница 12: ...ower Guide Bracket Assembly 4 1 112354 Check Valve Upper Moveable 5 1 116470 Street Elbow Pump NOT included under these part numbers The Moveable Assembly will be factory assembled to the pump when a Basin Package system is ordered MOVEABLE ASSEMBLY P N 116601 For SGPC UltraCAV Grider Pump with C Channel Rail ...

Страница 13: ...13 FIGURE 7 ...

Страница 14: ...242 39 A R Permatex 2C 41 A R Grease Food Grade 450 deg MP 48 1 105197 Snap Ring ITEM QTY PART NO DESCRIPTION 49 1 2 31051 224 O Ring 50 1 103760 113271 Terminal Block STD Terminal Block AU or Press Cutout 51 1 625 02117 Sleeving PRESSURE CUTOUT SWITCH OPTION 52 1 103759 Block Terminal 2Pin 53 1 113281 Switch Pressure Cutout 54 1 105147B Wire Jumper 10 55 1 105149 Wire Jumper 56 1 625 00163 Connec...

Страница 15: ...15 NOTES ...

Страница 16: ... A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If...

Отзывы: