INFINITY
4
AUTOBAR
2.3 Connecting the Electrical Supply
Safety First! Your machine must be earthed. On no account should it be earthed
only
to the water supply pipe.
Your machine must be connected to a 230 Volt 50Hz 13 amp fused switched socket outlet,
installed to the latest edition of the IEE regulations, using a 3 pin BS approved 13 amp fused plug.
Important: If the mains lead becomes damaged in any way it must be replaced by a special lead
available from the manufacturer.
Important: If any internal fuses become damaged or fail in any way they must be replaced by a
special fuse available from the manufacturer quoting the information written on the label adjacent
to the relevant fuse-holder
2.4 Commissioning Procedure
A trained installation engineer must carry out the following procedure before your machine can be
used for the first time. Ensure that the electrical and water services to the machine are connected
correctly. Check for leaks in the water supply.
1.
Open the front door of your machine.
2.
Ensure that the waste bucket is fitted correctly. Clip the level detector and overflow
pipes correctly onto the rim of the bucket.
3.
Cup Turret. Remove the cup stack assembly from its packaging and carefully place it
onto the cup drop unit, ensuring that the flat on the turret drive shaft locates with the
corresponding flat in the cup turret mounting block. Remove the lid and fill the tubes
with the correct size cups for the cup catcher type fitted to your machine. Allow the
cups to drop into the tubes directly from the packaging. DO NOT touch the cups with
your hands.
Important: Do not fill the tube directly above the cup dispense position. Allow the cup
turret motor to rotate a full tube to the cup dispense position when the machine is
powered up. Rotating the cup turret by hand will damage the mechanism.
Note: If you are loading paper cups, first inspect each pack for damage to the cup rims.
Damaged cups must not be used.
4.
The cup turret mechanism will index the first available full cup stack to the dispense
position and drop the cup stack into the cup drop mechanism. Fill the remaining empty
cup stack with cups and replace the lid.
5.
All Models: The water inlet valve will open and the heater tank will start to fill. As the
water heats, ensure that no water overflows from the heater tank overflow pipe into the
waste bucket. When the machine has powered up, the LCD will display the message
“Sorry Out of Service Water Tank Heating”. Check the system for leaks.
Note! The machine has a safety cut-out which will only allow the heater tank to fill for a
maximum of two minutes. If after software power-up the heater tank has not filled within
this time, the mains power supply should be switched off and then on again to reset the
heater tank time-out.
Important: Should the machine fail to fill correctly or leak, turn off the stopcock and the
power to the machine before investigating the fault.
6.
Check the LCD display on the front of the machine to ensure that the water has heated to the
correct temperature and that the machine is in standby mode. A machine set to free vend
mode will alternate the messages: “Please Make a Selection”/“No Money Required”.
Se
ctio
n
2
-In
sta
lla
tio
n
(E
ng
ine
erʼs
Pro
ce
du
re)
Содержание Autobar INFINITY
Страница 1: ...Part Number PR13176000 Issue NEW 3 10 Operatorʼs Manual INFINITY ...
Страница 2: ...INFINITY AUTOBAR ...
Страница 46: ...INFINITY 42 AUTOBAR ...
Страница 47: ...Operators Manual 43 A FRESH APPROACH TO VENDING ...