Ready to Measure
The WrenchStar Multi is now ready to measure torque.
Once the job is completed, the screen display on the
WrenchStar Multi will read ‘Wait’.
9
Crane Electronics Ltd
The force in torque management
Pairing on the IQVu
On the IQVu, press and hold one of the rows e.g. row
‘RF1’. An ‘Actions’ box will appear. Select the ‘Pair’
option. If pairing is successful, a row of information
will appear in yellow on the select a transducer screen.
6
Pair Mode
Ensure the WrenchStar Multi is in ‘pair’ mode by
pressing and holding down the blue ‘pairing’ button on
the wrench until the LED light turns purple.
5
Pairing on the IQVu cont.
The WrenchStar Multi LED will change from purple to
blue. Select the yellow highlighted row on the IQVu
screen, it will then turn green and say ‘connected’ then
it will take you straight to the job.
7
Connected Wrench
The sequence Green-Amber-Red on the WrenchStar
Multi light ring will confirm an OK connection and the
LED display on the Wrench will show how many ‘Jobs’
are ready to go.
8
IQVu Torque Data Collector
The IQVu provides the ideal solution for the measurement and
collection of torque, angle and pulse data in the manufacturing
and quality environments and offers complete traceability and
auditing capabilities.
For more information about the IQVu range, please visit
www.crane-electronics.com
.