6
INSTALLATION
Caster Assembly (Fig. C)
1. Remove the Powerhead Assembly from the Dust
Drum, and turn the Dust Drum upside down on the
floor.
2. Insert the Caster Stem into the Caster Socket, as shown
(4 places).
3. Push on the Caster until the Caster Stem Ball is
inserted all the way into the Caster Socket. You will
hear the Ball snap into the Socket and the Caster will
swivel easily when positioning is correct.
4. Turn the Dust Drum upright.
Fig. C
Dust
Drum
Caster
Caster
Stem
Caddy
Caster
Socket
Carry Handle Assembly (Fig. D)
1. Place the Carry Handle on the Wet/Dry Vac Powerhead
Assembly.
2. Tighten Two Screws to assemble the Carry Handle on
the Powerhead Assembly.
Screws (2)
Carry
Handle
Wet/Dry Vac
Powerhead
Assembly
Fig. D
Powerhead Assembly / Removal (Fig. E)
To Reattach Powerhead Assembly to Dust Drum:
1. Align the front of the Powerhead Assembly with the
Vacuum Inlet Port located on the front of the Dust
Drum.
2. Place the Powerhead Assembly on top of the Dust
Drum.
3. Ensure the Powerhead Assembly completely covers
the top of the Dust Drum so leakage does not occur.
4. Rotate the Drum Latch up and over the Powerhead
Assembly Hook to engage the Two Latches.
To Remove the Powerhead Assembly from the Dust
Drum:
Lift up on the Two Latches and remove from Powerhead
Assembly.
Fig. E
Dust
Drum
Latch
1. ROTATE DUST
DRUM LATCH UP
2. ROTATE
DUST DRUM
LATCH DOWN
Dust Drum Latch
Powerhead
Assembly Hook
Dust Drum
Handle
Dust
Drum
Handle
DRAI