14
ENGLISH
•
Unplug the saw.
•
Set the miter table at 0°.
• Pull out the lock button
and loosen bevel lock knob ,
tilt the cutting arm completely to the right. Tighten the
bevel lock knob .
•
Pull down the cutting head until the blade just enters
the table insert.
•
Place a framing square on the miter table and up
against the saw blade .
5
7
8
2
6
4
4
3
6
6
1
9
1
3
1
5
WARNING:
To avoid injury from an accidental start,
make sure the switch is in the OFF position and the
plug is not connected to the power source outlet.
Bevel stop adjustment (Fig. 16a-16c)
Miter scale (Fig. 17)
90° (0°) Bevel adjustment (Fig. 16a-16b)
90° (0°) Bevel pointer adjustment (Fig. 16c)
•
If the blade is not 90° (0°) square with the miter table,
loosen the bevel lock knob , tilt the cutting head
completely to the left, loosen two bolts on back of
saw with a 5 mm hex key (not supplied).
•
Tilt the cutting arm back to the right at 90° (0°) bevel
and recheck for alignment.
•
Repeat above steps if further adjustment is needed.
•
Tighten bevel lock knob and two bolts when
alignment is achieved.
•
When the blade is exactly 90° (0°) to the table, loosen
the bevel indicator screw using the wrench (supplied).
•
Adjust bevel indicator to the “0” mark on the bevel
scale and retighten the screw.
45° Bevel adjustment
•
If the 90° (0°) bevel have been set correctly, you do not
need to adjust the 45° bevel.
To adjust miter angles
•
Loosen the miter lock handle counterclockwise to
unlock the table and squeeze the miter latch lever .
•
Move the table to align the pointer to the desired
degree on miter scale .
•
Release the miter latch lever and tighten the miter
lock handle .
Miter angle pointer adjustment
•
Unplug the saw.
•
Move the miter table to the 0° positive stop.
•
Loosen the pointer screw and adjust the indicator
to the 0° mark on the miter scale and retighten the
screw.
The miter scale can be easily read, showing miter angles
from 0° to 52° to the left, and 0° to 60° to the right. The miter
saw table has nine of the most common angle settings with
positive stops at 0°, 15°, 22.5°, 31.6°, 45° (left) and 0°, 15°,
22.5°, 31.6°, 45°, 60° (right).
Fig. 16a
Fig. 16c
Fig. 17
Fig. 16b
2
3
4
5
2
6
2
7
1
1
5
3
4
2
3
2
4
8
9
6
1
2
Содержание CMXEMAX69434501
Страница 2: ......