English
10
Clearing a Jammed Staple (Fig. A)
WARNING: To reduce the risk of serious personal
injury, disconnect battery pack from tool before
making any adjustments, changing accessories,
servicing, or moving the tool.
Such preventative
safety measures reduce the risk of starting the
tool accidentally.
If a fastener becomes jammed in the nosepiece, keep the
tool pointed away from you and follow these instructions
to clear:
1. Remove battery pack from tool and engage trigger
lock‑off.
2. Rotate the stall release lever
6
on the tool to release
the driver blade and clear the jam. If tool is still jammed
follow steps 3‑9 listed below.
3. Press the pusher latch
9
and pull the magazine
8
down.
4. Tip the tool over until the staples slide freely out of
the magazine.
5. Remove bent staple, using pliers if necessary.
Worklights (Fig. A)
There is a worklight
5
located on each side of the nailer.
Worklights turn on upon depressing the contact trip.
nOTE:
These worklights are for lighting the immediate work
surface and are not intended to be used as flashlights.
lOW BATTERY inDiCATOR:
The left‑side worklight will
flash four consecutive times and then shut down to indicate
low battery.
JAMMED nAil inDiCATOR:
The right‑side worklight will
flash continually if a nail becomes jammed in the nosepiece
(see
Clearing a Jammed Nail
).
Stall Release (Fig. A)
If the nailer is used in harder wood where all available energy
in the motor is used to drive a fastener, the tool may stall. The
driver blade will not complete the drive cycle and the jam/
stall indicator will flash. Rotate the stall release lever
6
on the
tool and the mechanism will release.
nOTE:
The tool will disable itself and not reset until the
battery pack has been removed and reinserted. If the driver
blade does not automatically return to the home position,
proceed to
Clearing a Jammed Nail
. If the unit continues to
stall please review the material and fastener length to be sure
that it is not too rigorous an application.
The sequential actuation mode provides the most accurate
staple location.
1. Fully depress nosepiece against the work surface (motor
will start).
2. Pull trigger (a fastener will drive into work surface).
3. Release trigger.
4. Lift nosepiece off work surface.
5. Repeat steps 2 through 4 for next application.
NOTICE:
The contact trip needs to be depressed
followed by a trigger pull for each fastener followed
by a release of both the contact trip and trigger after
each fastener.
Stapling
WARNING:
Always wear proper eye [ANSI Z87.1 (CAN/
CSA Z94.3)] and ANSI S12.6 (S3.19) hearing protection
when operating tool.
WARNING:
Keep fingers AWAY from trigger when not
driving fasteners to avoid accidental firing.
The cordless staplers are assembled in accordance with the
ANSI Standard SNT‑101‑2015.
Non-Mar Tip (Fig. A)
WARNING:
Always remove battery pack before
attaching the non‑mar tip.
When using this tool on softer materials that you do not
want to mark, such as wood cladding, use the plastic non‑
mar tip
17
over the contact trip
7
.
Adjusting Depth (Fig. A)
The depth that the fastener is driven can be adjusted using
the depth adjustment wheel
3
on the nose of the tool.
WARNING: To reduce risk of serious injury from
accidental actuation when attempting to adjust
depth,
ALWAYS:
• Remove battery pack.
• Engage trigger lock‑off.
• Always point the nose of the stapler away
from you.
• Avoid contact with trigger during adjustments.
1. To drive the staple shallower, rotate the depth
adjustment wheel
3
to the right, toward the shallow
stapler icon.
2. To drive a staple deeper, rotate the depth adjustment
wheel
3
to the left, toward the deeper staple icon.
WARNING:
Always remove battery pack before
loading or unloading fasteners.
CAUTION:
Keep fingers clear of pusher latch track to
prevent injury.
WARNING:
The trigger lock‑off should always be
engaged whenever any adjustments are made or when
tool is not in use.
1. Turn the stapler upside down.
2. Press the pusher latch and pull magazine down.
3. Hold the stapler so the magazine is level and then insert
fasteners into the slot of the magazine as shown in
Figure G.
4. Push magazine closed until it locks into place.
Unloading the Tool
WARNING:
The trigger lock‑off should always be
locked off whenever any adjustments are made or
when tool is not in use.
1. Press the pusher latch
9
and pull the magazine down.
2. Tip the tool over until the staples slide freely out of
the magazine.
3. With battery removed, check the nosepiece to verify
there are no fasteners remaining.