20- ENG
D30339
D30339
6.
Air in hose.
6.
Turn off the engine, then
the water source.
Disconnect the water
source from the pump
inlet and turn the water
source on to remove all air
from the hose. When there
is a steady stream of
water present, turn water
source off. Reconnect
water source to pump inlet
and turn on water source.
Squeeze trigger to remove
remaining air.
7.
Choke lever in the
"Choke" position.
8.
Throttle control lever is
not in the "Fast" position.
9.
High pressure hose is too
long.
7.
Move choke to the "No
Choke" position.
8.
Move throttle control lever
to the "Fast" position.
9.
Use high pressure hose
under 100 feet.
PROBLEM
CAUSE
CORRECTION
No or low
pressure
(initial use)
(continued)
6.
Chemical build up in
chemical injector.
Will not draw
chemicals
1.
Wand not in low
pressure.
2.
Chemical filter clogged.
3.
Chemical screen not in
chemical
4.
Chemical too thick
5.
Pressure hose is too long
2.
Clean filter.
3.
Insure end of chemical
hose is fully submerged
into chemical.
4.
Dilute chemical. Chemical
should be the same
consistency as water.
5.
Lengthen water supply
hose instead of pressure
hose.
6.
Have parts cleaned or
replaced by AWSC.
1.
See How to Use Spay
Wand paragraph in the
Operation Section.