19-ENG
N000395
they are not, loosen the setscrew
of the motor drive pulley and
equalize B1 and B2, using care
not to disturb the belt alignment
performed in step 2.
8. Retighten the motor drive pulley
setscrew. See Parts manual for
torque specifications.
9. Reinstall
belt
guard.
AIR COMPRESSOR PUMP
INTAKE AND EXHAUST VALVES
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
INSPECT AIR LINES AND
FITTINGS FOR LEAKS
1. Turn air compressor off, lock out
the power supply, and relieve all
air pressure from the air tank.
2. Apply a soap solution to all air line
fittings and connections/piping.
3. Correct any leaks found.
IMPORTANT: Even minor leaks can
cause the air compressor to overwork,
resulting in premature breakdown or
inadequate performance.
AIR COMPRESSOR HEAD
BOLTS - TORQUING
The air compressor pump head bolts
should be kept properly torqued.
Check the torques of the head bolts
after the first five hours of operation.
Retighten if necessary. See Parts List
for torque specifications.
1. Turn air compressor off, lock out
the power supply, and relieve all
air pressure from the air tank.
2. Remove
belt
guard.
3. Place a straightedge against the
outside of the flywheel and the
motor drive pulley.
4. Measure the distance between
the edge of the belt and the
straightedge at points A1 and A2
in figure. The difference between
measurements should be no more
than 1/16" (1.6 mm).
5. If the difference is greater than
1/16" (1.6 mm) loosen the set
screw holding the motor drive
pulley to the shaft and adjust the
pulley’s position on the shaft until
the A1 and A2 measurements
are within 1/16" (1.6 mm) of each
other.
6. Tighten the motor drive pulley
set screw. See Parts manual for
torque specifications.
7. Visually inspect the motor drive
pulley to verify that it is perpen-
dicular to the drive motor shaft.
Points B1 and B2 of Figure
should appear to be equal. If
SERVICE AND ADJUSTMENTS
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of Unsafe
Operation. Unit
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
TO REPLACE OR CLEAN CHECK
VALVE
1. Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2. Turn air compressor off, lock out
the power supply, and relieve all
air pressure from the air tank.
3. Using an adjustable wrench loos-
en outlet tube nut at air tank and
pump. Carefully move outlet tube
away from check valve.
Содержание 919.167810
Страница 50: ...50 N000395 NOTES NOTAS ...