4. Using an adjustable wrench, loos-
en outlet tube nut at air tank and
pump head. Carefully move outlet
tube away from check valve.
Nuts
Outlet
Tube
Check
Valve
5. Unscrew the check valve (turn
counterclockwise) using a 7/8"
open end wrench.
6. Install the new check valve (turn
clockwise).
7. Replace the outlet tube and
tighten nuts.
8. Replace the shroud.
SERVICE AND ADJUSTMENTS
Risk of Unsafe
Operation. Unit
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED BY TRAINED
SERVICE TECHNICIAN.
TO REPLACE CHECK VALVE
1. Release all air pressure from air
tank. See
To Drain Tank
in the
Maintenance section.
2. Unplug outfit.
3. Remove the shroud on the outlet
tube side.
NOTE:
Remove screw
with T-20 Torx screwdriver and
loosen all the tabs on the shroud
with a flat screwdriver before
removing.