OM-194 199 Page 9
2-9.
Installing Wire Spool And Adjusting Hub Tension
ST-072573-B
When a slight force is needed
to turn spool, tension is set.
15/16 in
Use compression spring with
8 in (200 mm) spools.
Tools Needed:
2-10. Changing Input Voltage
ST-801 580-A
Y
Turn Off unit, and disconnect
input power.
Unit was shipped from factory set
for 230 volts.
1
Transformer T1
2
Rear Of Power Switch S1
3
Lead Marked 230 Volt And
Fan Motor Lead
Disconnect 230 volt lead and fan
motor lead from rear of S1. Leave
fan motor lead connected to 230
volt lead.
4
Lead Marked 200 Volt
Remove cable tie, and slide short
piece of sleeving off 200 volt lead,
and slide sleeving over end of 230
volt and fan motor leads. Fold
sleeving over and secure in place.
Connect 200 volt lead to S1 where
230 volt lead was removed.
Reinstall wrapper.
3/8, 7/16 in
1
Tools Needed:
2
3
4