3. Installation Preparation.

7 feet

(2.13 m) (76 cm)

30 

inches

12 ft. - 15 ft.

(3.66 m - 4.57 m)

blade edge

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13 m) from the floor and 
30 in (76 cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 225 square 
feet (20.9 square meters).

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

This fan can be mounted as a 

flushmount

on a regular (no-slope) ceiling 

only

Downrod 

installations are 

not

 available for this fan.

downrod

installation

flushmount

installation

CANNOT be

installed on

angled or

vaulted ceilings

4. Mounting Plate Installation.

ON

OFF

ON

OFF

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure the outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

Be sure outlet box is grounded properly and that 

a ground wire (

GREEN

 or bare) is present.

Install mounting plate to outlet box using original screws, 
spring washers and flat washers provided with new or 
original outlet box. *Pull electrical wiring from outlet box 
through center hole in mounting plate.

*Note

: It is very important that you use the proper hardware 

when installing the mounting plate as this will support the 
fan. 

spring washers

flat washers

outlet box screws

mounting plate

12 f

t.

 - 15 f

t.

(3.66 m - 4.57 m)

Содержание Warbirds WB348

Страница 1: ...Table of Contents Safety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Mounting Plate Installation pg 3 Fan Assembly pg 4 Wiring pg 5 Attachment of Motor Housin...

Страница 2: ...our house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrica...

Страница 3: ...should this fan need to be returned for repairs Check against parts inventory that all parts have been included 2 Parts Inventory bulb required 1 x 60 watt max candelabra base bulb included IMPORTANT...

Страница 4: ...aker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNIN...

Страница 5: ...n the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with t...

Страница 6: ...th wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wir...

Страница 7: ...ten screws securely with Phillips screwdriver Repeat procedure for remaining blades Note Tighten blade arm screws twice a year Install one candelabra base 60 watt max bulb included Locate slots on sha...

Страница 8: ...ing Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season UP position in summer diagram 2 DOWN position in winter diag...

Страница 9: ...epaid to Craftmade Ellington We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE ELLINGTON will repair or replace at no charge to the origin...

Страница 10: ...el ventilador P g 2 Inventario de piezas P g 2 Preparaci n para la instalaci n P g 3 Instalaci n de la placa de montaje P g 3 Ensamblaje del ventilador P g 4 Instalaci n el ctrica P g 5 Colocaci n del...

Страница 11: ...ipales del ventilador Si el calibre del cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar...

Страница 12: ...eparaci n Comprobar las piezas del ventilador con el inventario de piezas y verificar que se incluyeron todas 2 Inventario de piezas a placa de montaje 1 unidad b bastidor del motor 1 unidad c aspa 3...

Страница 13: ...trico los cables de la caja de salida por el agujero de en medio de la placa de montaje Nota Es muy importante usar los art culos de ferreter a correctos al instalar el soporte de montaje puesto que s...

Страница 14: ...omienda la viga de madera en el techo y asegurar el cable de seguridad Utilizar tornillo para madera para trabajos pesados arandela y arandela de seguridad no provistos en el bucle del cable de seguri...

Страница 15: ...para cable provisto Conectar el cable BLANCO del ventilador al cable BLANCO del techo con un conector para cable provisto Conectar todos los conductores a TIERRA VERDES del ventilador al cable PELADO...

Страница 16: ...horrar tiempo Se pueden poner las arandelas en los tornillos que son para las aspas antes de colocar las aspas Localizar los tornillos para fijar las aspas y las arandelas en uno de los paquetes de ar...

Страница 17: ...las antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependiendo de las estaciones...

Страница 18: ...r abuso mec nico f sico el ctrico o por agua resultando en su mal funcionamiento Se exenta espec ficamente el deterioro en el acabado u otras partes debido al tiempo o exposici n al aire marino bajo e...

Отзывы: