4. Hanging Bracket Installation.

page 4

3. Installation Preparation.

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, adjustable 
pliers or wrench, stepladder, wire cutters, and rated 
electrical tape.

downrod

installation

flushmount

installation

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13m) from the floor and 
30in. (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

7 feet

(2.13 m) (76 cm)

30 

inches

blade edge

12f

t.

 - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

Vaulted ceiling 
angle is not to 
exceed 20 degrees.  

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing a 
longer downrod (0.5in./1.27cm diameter). 

After 

installing hanging bracket,

 c

ontinue to Section 5 on 

page 4 for those instructions.  

This fan can also be 

mounted as a 

flushmount

 on a regular (no-slope) 

ceiling. 

After installing hanging bracket, continue to 

Section 6 on page 5 for those instructions.

ON

OFF

ON

OFF

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

: Be sure outlet box is properly grounded and that a 

ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original screws, 
spring washers and flat washers provided with new or 
original outlet box.

If installing on a vaulted ceiling, face 

opening of hanging bracket towards high point of ceiling. 
Arrange electrical wiring around the back of the hanging 
bracket and away from the bracket opening.

*Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the 
fan. 

hanging bracket

spring washers

outlet box screws

flat washers

Содержание TEA52

Страница 1: ...afety Tips pg 2 Unpacking Your Fan pg 3 Parts Inventory pg 3 Installation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 7 Wiring Wall Control pg 7 Canopy Assembly p...

Страница 2: ...ith a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until the fan has come to a complete s...

Страница 3: ...that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball with pin and clip 1 piece d yoke cover 1 piece e wall control 1 piece f plate...

Страница 4: ...tion 6 on page 5 for those instructions ON OFF ON OFF Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure t...

Страница 5: ...set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires through hanging ball then slide hanging ball over downrod the...

Страница 6: ...t over the threads on the wood screw Test safety cable by pulling on loose end with pliers If the safety cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area han...

Страница 7: ...tch connect BLUE wire from fan to the BLACK or RED supply from the independent switch Wrap each wire connector separately with electrical tape as an extra safety measure white black supply wire white...

Страница 8: ...nopy to lock Re insert the other 2 screws washers and secure all screws with a Phillips screwdriver canopy hanging bracket slotted hole motor housing blade arm blade blade attachment screws and washer...

Страница 9: ...d securely tighten all 3 screws with a Phillips screwdriver Locate slots on glass shade and align with nodules on inside of fitter plate Gently push up on glass shade and turn to the RIGHT clockwise u...

Страница 10: ...ty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or s...

Страница 11: ...alaci n del soporte de montaje P g 4 Ensamblaje del ventilador P gs 5 6 Instalaci n el ctrica P g 7 Instalaci n el ctrica control de pared P g 7 Colocaci n de la cubierta decorativa P g 8 Colocaci n d...

Страница 12: ...ENCIA para reducir el riesgo de incendio o un choque el ctrico no usar el ventilador con ning n control de velocidad de estado s lido ni controlar la velocidad del ventilador con un interruptor con re...

Страница 13: ...as 2 Inventario de piezas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 unidad b soporte...

Страница 14: ...on el paso 6 en la p gina 5 para esas instrucciones Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO...

Страница 15: ...agujeros para el perno y la clavija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornil...

Страница 16: ...se reduce el bucle del cable por donde pasa el tornillo hay que ajustar el bucle de nuevo Se puede poner el cable en exceso en el rea del techo ranura en la bola que sirve para colgar parte saliente...

Страница 17: ...ductor NEGRO o ROJO que corresponde al interruptor independiente Como una medida de seguridad adicional envolver cada conector para cable por separado con cinta aisladora toma de tierra verde o pelada...

Страница 18: ...a para cerrarla Volver a introducir los otros 2 tornillos arandelas y asegurar todos los tornillos con un destornillador de estrella Phillips soporte de montaje cubierta decorativa agujero con ranura...

Страница 19: ...lizar las ranuras en la pantalla de vidrio y alinear las ranuras en la pantalla de vidrio con los n dulos en la parte interior de la placa de conexi n Empujar la pantalla de vidrio suavemente hacia ar...

Страница 20: ...ara uso interior con las siguientes condiciones GARANTIA DE 1 A O CRAFTMADE reemplazar o reparar cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo...

Отзывы: