5. Fan Assembly. (cont.)

6. Wiring.

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with 
Local Codes or Ordinances and the National 
Electrical Code. If you are unfamiliar with electrical 
wiring or if the house/building wires are different 
colors than those referred to in the diagram to the 
right, please use a qualified electrician.

When downrod is secured in place on the 
hanging bracket, wire the

 RECEIVER

 with wire 

connectors provided 

as shown in

 

diagram at 

right.

Tip

: While you are wiring, keep in mind that 

wires must not obstruct receiver from sliding 
into hanging bracket.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

Gently insert receiver (flat side up) into hanging 
bracket and carefully push wires and taped wire 
connectors into outlet box. Let antenna rest 

outside 

of hanging bracket.

["Wiring" continued on next page.]

blue

black

AC IN L

whit

e

ground (green

or bare)

antenna

(wiring for receiver)

black

receiver

black

black

from receiver

from fan

white

white

blue
orange

from

 ceiling

from receiver

black supply wire 

white supply wire

orange

ground (green

or bare)

AC IN N

white

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging 
ball rest on the hanging bracket. Turn the hanging ball 
slot until it lines up with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab 

in hanging bracket may result in serious injury or death.

Tip:

 Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you 
once you are set on the ladder. 

Find a secure attachment point (wood ceiling joist 
highly recommended) and secure safety cable. It will be 
necessary to use a heavy duty wood screw, washer and 
lock washer (not supplied) with the safety cable loop. If 
necessary, adjust the loop at the end of the safety cable. 
The loop at the end of the safety cable should just fit 
over the threads on the wood screw. Extra cable slack 
can be left in ceiling area. 

wood

ceiling

joist

hanging ball slot

hanging bracket tab

motor housing

safety cable

wood screw

and washer

safety cable loop

canopy

Содержание SE68SPZ

Страница 1: ...Arm Assembly pg 7 Blade Assembly pg 7 Switch Housing Assembly pg 8 Automated Learning Process Activating Code pg 9 Wall Control Operation pg 10 Remote Control Operation pg 10 Testing Your Fan pg 11 Troubleshooting pg 12 Warranty pg 12 Parts Replacement pg 12 Installation Guide PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE For Model SE68SPZ net weight of fan 32 01 lb 14 52 k...

Страница 2: ...re than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use with the model fan you are installing Switches must be CUL Canada or UL USA general use switches Refer to the i...

Страница 3: ...ll arm 3 pieces p safety cable already attached to motor 1 piece q canopy cover in hardware pack 1 piece r hardware packs page 2 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check agai...

Страница 4: ...disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for Fan Support of 22 68 kg 50lbs or Less and use mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan sup...

Страница 5: ... stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Tip To prepare for threading electrical wires through downrod apply a small piece of electrical tape to the ends of the electrical wires this will keep the wires together when threading them through the downrod Locate sockets inside top of motor housing Install 4 candelabra base 15 watt max bulbs included Impo...

Страница 6: ...om receiver from fan white white blue orange from ceiling from receiver black supply wire white supply wire orange ground green or bare AC IN N white With the hanging bracket secured to the outlet box and able to support the fan you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Tur...

Страница 7: ... each wire connector separately with electrical tape as an extra safety measure Gently push wires and taped wire connectors into outlet box Use a ballpoint pen or a small screwdriver to set the code switches 1 through 4 on the wall control Factory setting is pre set and not recommended for use Write down the number sequence to use in Section 10 Note The dimmer switch labeled D and X has been pre s...

Страница 8: ...anently repeat with remaining blade arms Securely tighten all screws Note Tighten blade arm screws twice a year scroll arm support scroll arm support scroll arm motor housing 8 Scroll Arm Assembly Remove 3 decorative screws from inside top of motor housing Remove decorative screws from scroll arm support Attach scroll arm to motor housing first Align hole in larger end of one of the scroll arms wi...

Страница 9: ...n center of switch housing plate with loosened screws in fitter plate allowing male plug from motor housing to come through hole in middle of switch housing plate Twist switch housing plate to lock Re insert screw that was removed and secure all screws Connect male plug from motor housing to female plug from switch housing Make sure plugs connect tightly Align holes in switch housing with holes in...

Страница 10: ...or the transmitter Use the same number sequence used when wiring the wall control in Section 6 page 6 Note The dimmer switch labeled D and X has been pre set to the ON position D If you do not wish to have dimming capability please move the switch to the OFF position X Install one 12 volt battery included in transmitter and then re attach the battery cover IMPORTANT Store the transmitter away from...

Страница 11: ...hen pressed once dims upper light when pressed and held down REV button used to REVERSE blade direction fan must be set on low before reversing blade direction L1 L1 L2 L2 HI button turns fan to HIGH speed MED button turns fan to MEDIUM speed LOW button turns fan to LOW speed button used to REVERSE blade direction fan must be set on low before reversing blade direction button turns fan OFF L1 butt...

Страница 12: ...own the L1 button for more than 2 seconds repeat with the L2 button If the remote control operates all of the functions of the fan and light battery has been installed correctly If the wall and or remote controls do does not operate all of the fan light functions please refer to Troubleshooting section to solve any issues Fan must be on LOW before setting the fan to reverse direction Use reverse b...

Страница 13: ...t air is specifically exempted under this warranty Neither Craftmade Ellington nor the manufacturer will assume any liability resulting from improper installation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to consequential damages shall not apply in states wh...

Отзывы: