background image

page 10

11. Automated Learning Process./Activating Code.

wall control

faceplate
(almond 
or white)

I

II

IV

VI

III

V

OFF

ON

SET button

faceplate

(black)

handheld

remote control

I

II

IV

VI

III

V

OFF

ON

SET button

CAUTION

:

 The wall and/or handheld remote control 

can be programmed to multiple receivers or fans. If 
this is not desired, turn wall switch off to any other 
programmable receiver or fan.

Restore electrical power and then, if using wall 
control, set slider switch on wall control to the ON 
position. Within 60 seconds of turning on the wall 
control, press and hold the fan 

SET 

button on the 

wall control for 5 seconds or until light blinks 
twice.

Turn power off again for at least 5 seconds

 and 

then turn power back on. Within 60 seconds of 
restoring the power, press and hold the fan 

SET

 

button on the handheld remote control for 
5 seconds or until light blinks twice.

Test the light and fan functions to confirm the 
learning process is complete -- 

see Section 13 on the 

following page.

Select a faceplate (

almond or white

) and press 

firmly onto front of wall control that was previously 
installed to the outlet box on the wall. [

Refer to 

diagram 1

.

]

Attach 

black faceplate

 to front of handheld remote 

control; press down firmly. [

Refer to 

diagram 2

.

]

diagram 1

diagram 2

       

CAUTION:

 “DO NOT DISPOSE OF BATTERIES IN FIRE, BATTERIES MAY EXPLODE OR 

LEAK.” - When disposing of household alkaline batteries, it is best to check with your local and 

state recycling or household hazardous waste coordinators concerning the specifics of the 

program in your area. You may also locate a recycling center by calling 1-800-8-BATTERY or 

1-877-2-RECYCLE or visit www.epa.gov/epawaste/index.htm or www.earth911.org for more 

information.

Содержание MAR52

Страница 1: ...5 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Light Kit Assembly pg 8 Handheld Remote Control Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Wall Control Operation pg 1...

Страница 2: ...l device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until f...

Страница 3: ...included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e canopy cover 1 piece f yoke cover 1 piece g fitter plate 1 piece h L...

Страница 4: ...t towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when insta...

Страница 5: ...gram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously remove...

Страница 6: ...er in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heav...

Страница 7: ...perate If you do not wish to use the wall control please proceed to Section 7 page 7 to continue with fan installation To install wall control remove existing wall switch Wire one of the wall controls...

Страница 8: ...sk of serious bodily injury DO NOT use power tools to assemble the blades If overtightened blades may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to instal...

Страница 9: ...from the LED light kit matching up the colors on the male plug with the colors on the female plug for correct fit Make sure that plugs connect securely Carefully arrange wiring within the back of LED...

Страница 10: ...sition If you do not wish to have dimming capability please move the switch to the OFF position D Align holes in wall control with posts located on inside of TOP part of remote control cover and press...

Страница 11: ...the power press and hold the fan SET button on the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm the learning process is complete see Se...

Страница 12: ...e remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting...

Страница 13: ...ailure to disconnect power supply prior to troubleshooting any wiring issues may result in serious injury Parts Replacement For parts and information please refer to Parts Inventory on page 2 Craftmad...

Страница 14: ...ego de luz LED P g 8 Ensamblaje del control remoto de mano P g 9 Proceso de aprendizaje autom tico Activar el c digo P g 10 Funcionamiento del control remoto de pared P g 11 Verificaci n del funcionam...

Страница 15: ...equipo al lado opuesto ADVERTENCIA para reducir el riesgo de incendio o un choque el ctrico no usar el ventilador con ning n control de velocidad de estado s lido ni controlar la velocidad del ventila...

Страница 16: ...ECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 unidad b soporte de montaje 1 unidad c tubo...

Страница 17: ...Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota es muy importante usar los art culos de ferreter a correctos al instalar el soporte...

Страница 18: ...ver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Localizar la tapa de la cubierta dec...

Страница 19: ...listo en la escalera para colgarlo Encontrar un punto de acoplamiento seguro se recomienda la viga de madera en el techo y asegurar el cable de seguridad Utilizar tornillo para madera para trabajos pe...

Страница 20: ...a verde o pelada conector para cable del ventilador interruptor del reductor de luz I II IV VI III V verde negro tierra verde pelado placa cableado del control de pared caja de salida control de pared...

Страница 21: ...sta que ya no gire ADVERTENCIA para reducir el riesgo de lesiones corporales graves NO utilice herramientas el ctricas para ensamblar las aspas Si aprieta demasiado las aspas estas podr an agrietarse...

Страница 22: ...ndo combinar los colores del enchufe macho con los del enchufe hembra para un ajuste correcto Asegurarse de que se conecten bien los enchufes Cuidadosamente arregle los cables dentro del juego de luz...

Страница 23: ...encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los po...

Страница 24: ...onectado la electricidad oprimir el bot n SET en el control remoto de mano por 5 segundos o hasta que la luz parpadee dos veces Poner a prueba las funciones de luz y ventilador para confirmar que se h...

Страница 25: ...TA si el control de pared control remoto de mano interfiere con otros aparatos activar un c digo nuevo en el control de pared control remoto de mano cortando la corriente primero Repetir las instrucci...

Страница 26: ...ater a en el control de pared Problema el ventilador se tambalea Soluciones 1 Usar el juego para balancear las aspas incluido en uno de los paquetes de art culos de ferreter a Si no se incluye un jueg...

Отзывы: