background image

SAFETY TIPS.

page 2

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin 

the fan installation or before servicing the fan or installing accessories.

  
1.         

READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE 

INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.  

If you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the 
instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven (7) feet 

(2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be mounted so that the tips of the blades 
are at least thirty (30) inches (76 centimeters) from walls or other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16 

kilograms).  The box must be supported directly by the building structure.  Use only CUL (Canada) or UL (USA) listed outlet 
boxes marked "FOR FAN SUPPORT."

  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 

15.9 kg (35 lb) or less" and use the mounting screws provided with the outlet box.  Most outlet boxes commonly used for the support of 
lighting fixtures are not acceptable for fan support and may need to be replaced.  Consult a qualified electrician if in doubt.

  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept 

only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one 
house wire to connect to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

  
5.         Electrical diagrams are for reference only.  
6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.  

The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides 
of the outlet box.

  

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or control fan 

speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud humming noise from 
fan.]

  
8.        Do not operate the reverse switch until fan has come to a complete stop. [

Note

: If using remote control with reverse capability, 

reverse fan blade direction only when on LOW speed.]

9.        Do not insert anything between the fan blades while they are rotating.

  

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do not insert objects 

into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

  
10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable 

for most cleaning.

  

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER than those provided 

with this fan will void the warranty.

  
WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in 

personal injury, damage to the fan or damage to other property.

  

CAUTION

: Do NOT tamper with or attempt to repair LED component of light kit. The light source is designed for this specific application 

and should not be serviced by untrained personnel. If any servicing is required, call our customer service department.

  
11.       Light kit is d

immable to 10% with select dimmers.

 

Modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. [The 
equipment refers to the remote and/or wall control and/or LED light kit.]

 

NOTE

: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 

* Reorient or relocate the receiving antenna.

 

* Increase the separation between the equipment and receiver.

 

* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
* Consult the dealer or an experienced radio/TV technician for help.

   

 

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and 

situations that may occur.  It must be understood that common sense and caution are necessary factors in the installation and 
operation of this fan.

Содержание Echelon ECH54

Страница 1: ...nstallation pg 4 Fan Assembly pgs 5 6 Wiring pg 7 Canopy Assembly pg 8 Blade Assembly pg 8 Light Kit Assembly Optional pg 8 Handheld Remote Control Assembly pg 9 Automated Learning Process Activating Code pg 11 Remote Wall Control Operation pg 12 Testing Your Fan pg 12 Troubleshooting pg 13 Warranty pg 13 Parts Replacement pg 13 E192641 net weight of fan 17 86 lb 8 10 kg WARNING DC Motor will not ...

Страница 2: ...ontrol fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while they are rotating WARNING To reduce the risk of personal injury do not bend the blade arms during assembly or ...

Страница 3: ... b hanging bracket 1 piece c downrod and hanging ball 1 piece d canopy cover in hardware pack 1 piece e motor housing 1 piece f yoke cover 1 piece g fitter plate 1 piece h LED light kit 1 piece i glass shade 1 piece j metal cover 1 piece k blade plate 3 pieces l blade arm 3 pieces m blade 3 pieces n wall control 2 pieces o plate 1 piece p remote control cover 1 piece q faceplate 3 pieces r hardwar...

Страница 4: ...et towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan Installation requires these tools Phillips screwdriver flathead screwdriver adjustable pliers or wrench stepladder wire cutters and rated electr...

Страница 5: ...agram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Locate canopy cover in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be ...

Страница 6: ...der in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with the safety cable loop If necessary adjust the loop at the end of the safety cable The loop at the end of the safety cable should just fit ov...

Страница 7: ...e control must be used for fan to operate If you do not wish to use the wall control please proceed to Section 7 page 8 to continue with fan installation To install wall control remove existing wall switch Wire one of the wall controls with wire connectors provided as shown in diagram at right Wrap each wire connector separately with electrical tape as an extra safety measure Gently push wires and...

Страница 8: ...ightened blades may crack and break Locate blade attachment screws washers in hardware pack Hold blade arm up to blade and align holes Place blade plate on top of blade aligning posts in blade plate with holes in blade as shown and insert 3 blade attachment screws washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Locate 6 blade ...

Страница 9: ... connect the molex connections Carefully arrange wiring within the back of LED light kit Align slotted holes in LED light kit with loosened screws in fitter plate Twist LED light kit to lock Re insert screw that was previously removed and tighten all 3 screws securely Refer to diagram 2 Locate slots on glass shade and align with nodules on inside of LED light kit Gently push up on glass shade and ...

Страница 10: ...ace wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to align narrower ends of remote control cover before closing Squeeze top and bottom of remote control cover together until you hear a click at each end indicating that the remote control cover has closed completely IMPORTANT Store ...

Страница 11: ...0 seconds of turning on the wall control press and hold the fan SET button on the wall control for 5 seconds or until light blinks twice Turn power off again for at least 5 seconds and then turn power back on Within 60 seconds of restoring the power press and hold the fan SET button on the handheld remote control for 5 seconds or until light blinks twice Test the light and fan functions to confirm...

Страница 12: ...he remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting section to solve any issues before contacting Customer Service Fan must be on LOW before setting the fan in reverse Use button to recirculate air depending on the season A ceiling fan will allow you ...

Страница 13: ...WARNING Failure to disconnect power supply prior to troubleshooting any wiring issues may result in serious injury Parts Replacement For parts and information please refer to Parts Inventory on page 3 Craftmade Customer Support 1 800 486 4892 www craftmade com CRAFTMADE LIFETIME LIMITED WARRANTY CRAFTMADE warrants this fan to the original household purchaser for indoor use under the following prov...