7. Wiring.
page 6
black
black
from fan
from ceiling
white
white
blue
black supply wire
ground (green
or bare)
white supply wire
*
ground
(green or bare)
8. Canopy Assembly.
Raise canopy to hanging bracket, aligning
slotted holes in canopy with loosened screws
in hanging bracket. Twist canopy to lock.
Insert screws (with star washers) that were
previously removed (page 3, Section 4) and
secure all screws with Phillips screwdriver.
canopy
hanging bracket
slotted
hole
CAUTION
:
Be sure outlet box is properly grounded
and that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to in the instructions
below, please use a qualified electrician.
Note
:
Excess lead wire length from the fan can be
cut to the desired length and then stripped.
When downrod is secured in place on the
hanging bracket, electrical wiring can be made as
follows:
Connect
BLACK
and
BLUE
wires from fan to
BLACK
wire from ceiling with wire connector
provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together
from fan to
BARE
/
GREEN
wire from ceiling with
wire connector provided.
If you intend to control the fan light with a
separate light switch connect
BLUE
wire from fan
to the
BLACK
(or
RED
) supply from the
independent switch.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote control
sold separately).