10. Light Kit Assembly (Optional).

Remove 3 screws from switch housing cap.

[Refer to diagram 1.]

If you wish to use fan WITHOUT the light 

kitalign holes in switch housing cap with 

holes in switch housing. [Note: The gap on 

the top edge of the switch housing cap

must align with the reverse switch on the 

switch housing for the proper fit.] Secure 

switch housing cap with 3 screws that were 

just removed. [Refer to diagram 1.Please 

proceed to Section 11 on the following page to 

complete installation.

If you wish to use fan WITH the light kit

remove hex nut and lock washer from 

threaded rod at top of light kit fitter. Punch 

center cap out of switch housing cap with a 

screwdriver. Feed wires from light kit fitter 

through center hole in switch housing cap. 

Then, screw switch housing cap onto 

threaded rod followed by lock washer and 

hex nut. Tighten hex nut over lock washer 

for a secure fit. [Refer to diagram 2.]

Locate BLACK (or BLUE) and WHITE wires 

in switch housing labeled FOR LIGHT. 

Connect WHITE wire from switch housing 

to WHITE wire from light kit fitter. Connect 

BLACK (or BLUE) wire from switch housing 

to BLACK wire from light kit fitter. Be sure 

molex connections snap together 

completely. [Refer to diagram 3.]

Align holes in light kit fitter with holes in 

switch housing. [Note: The gap on the top 

edge of the switch housing cap must align 

with the reverse switch on the switch 

housing for the proper fit.] Attach light kit 

fitter with screws that were previously 

removed. Securely tighten all 3 screws with 

a Phillips screwdriver. [Refer to diagram 3.]

Install 2 medium base 5.5 watt LED bulbs 

(included). [Refer to diagram 3.]

IMPORTANT: When you need to replace 

bulbs, please allow bulbs and shade to cool 

down before handling.

["Light Kit Assembly" continued on next 

page.]

switch

housing

switch housing

cap

motor housing

threaded

rod

diagram 1

diagram 2

center cap

switch housing

cap

hex nut

lock washer

light kit fitter

switch housing

cap

bulb

diagram 3

motor housing

switch

housing

black

wire

black

(or blue)

wire

white

wire

molex

connections

white

wire

light kit fitter

reverse

 switch

Содержание DCF52 5C1W Series

Страница 1: ...4 Fan Assembly pgs 5 6 Wiring pg 7 Canopy Assembly pg 7 Blade Assembly pg 8 Light Kit Assembly Optional pgs 9 10 Testing Your Fan pg 10 Troubleshooting pg 11 Parts Replacement pg 11 Warranty pg 11 net weight of fan 16 2 lb 7 35 kg For Models DCF52XXX5C1W Installation Guide READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Decorator s Choice page 1 4007498 ...

Страница 2: ...ed and marked suitable for use with the model fan you are installing Switches must be ETL or UL general use switches Refer to the instructions packaged with the light kits and switches for proper assembly 6 After installation is complete check that all connections are absolutely secure 7 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the...

Страница 3: ... pre attached to canopy 1 piece c downrod and hanging ball with pin and clip 1 piece d motor housing 1 piece e blade arm 5 pieces f switch housing cap 1 piece g blade 5 pieces h light kit fitter 1 piece i shade 1 piece j finial plate pre attached to light kit fitter 1 piece k finial pre attached to light kit fitter 1 piece l hardware packs IMPORTANT REMINDER You must use the parts provided with th...

Страница 4: ...ent fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure outlet box is clearly ma...

Страница 5: ...extra wire slack from the upper end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nut securely Refer to diagram 2 Slide canopy over downrod Refer to diagram 3 Thread safety cable and wires ...

Страница 6: ...al 6 holes Refer to diagram 1 Notice that 3 of these holes are larger If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor housing remove every other screw and lock washer Thread wiring through canopy Place canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and ...

Страница 7: ...re connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK or RED supply from the independent switch Wrap each wire connector separatel...

Страница 8: ...g with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws and lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washers to secure blade arms Align blade arm holes with motor screw holes and attach blade...

Страница 9: ...ITE wires in switch housing labeled FOR LIGHT Connect WHITE wire from switch housing to WHITE wire from light kit fitter Connect BLACK or BLUE wire from switch housing to BLACK wire from light kit fitter Be sure molex connections snap together completely Refer to diagram 3 Align holes in light kit fitter with holes in switch housing Note The gap on the top edge of the switch housing cap must align...

Страница 10: ...e switch is set in the middle position diagram 4 fan will not operate Attach pull chain extension s supplied or custom pull chain extension s sold separately to end s of the pull chain s 11 Testing Your Fan Remove finial finial plate hex nut flat washer and rubber washer from threaded rod at bottom of light kit fitter Place rubber washer inside shade over center hole Raise shade in order to guide ...

Страница 11: ...ontact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR...

Страница 12: ...g 4 Instalación del soporte de montaje Pág 4 Ensamblaje del ventilador Págs 5 6 Instalación eléctrica Pág 7 Colocación de la cubierta decorativa Pág 7 Colocación de las aspas Pág 8 Instalación del juego de luz opcional Págs 9 10 Verificación del funcionamiento del ventilador Pág 10 Localización de fallas Pág 11 Piezas de repuesto Pág 11 Garantía Pág 11 Decorator s Choice LEER ESTAS INSTRUCCIONES Y...

Страница 13: ... Los juegos de luz que no se incluyen con el ventilador deben tener el símbolo ETL o UL y también deben indicar que sirven para uso con este ventilador Los interruptores deben ser interruptores de uso general ETL o UL Referirse a las instrucciones incluidas con el juego de luz y los interruptores para ensamblarlos correctamente 6 Después de haber terminado la instalación asegurarse de que todas la...

Страница 14: ...ve para colgar con perno y clavija 1 unidad d bastidor del motor 1 unidad e brazo para el aspa 5 unidades f cubierta de la caja de encendido 1 unidad g aspa 5 unidades h conectador para el juego de luz 1 unidad i pantalla 1 unidad j placa del adorno con rosca fijada de antemano al conectador para el juego de luz 1 unidad k adorno con rosca fijado de antemano al conectador para el juego de luz 1 un...

Страница 15: ...a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida existente asegurarse de que la caja de salida esté firmemente conectada a la estructura del edificio y que sea capaz de sostener el pes...

Страница 16: ...r la cubierta decorativa por el tubo Referirse al diagrama 3 Pasar los cables por la bola que sirve para colgar luego deslizar la bola que sirve para colgar sobre el tubo la parte de arriba del tubo debe tener el agujero para el tornillo de fijación en ese extremo usar ese agujero al colocar el tornillo de fijación Introducir el perno de tope en la parte de arriba del tubo y subir la bola que sirv...

Страница 17: ... en la parte de arriba del bastidor del motor favor de pasar al párrafo siguiente Si hay 6 tornillos en la parte de arriba del bastidor del motor quitar cada otro tornillo y arandela de seguridad Pasar el cableado por la cubierta decorativa Colocar la cubierta decorativa encima del cuello alineando los agujeros más grandes en la cubierta decorativa con los 3 tornillos existentes en la parte de arr...

Страница 18: ... ventilador al cable BLANCO del techo con un conector para cable provisto Conectar todos los conductores a TIERRA VERDES del ventilador a los PELADOS VERDES del techo con un conector para cable provisto Si usted piensa controlar la luz del ventilador con un interruptor distinto conectar el cable AZUL del ventilador al conductor NEGRO o ROJO que corresponde al interruptor independiente Como una med...

Страница 19: ...rnillos para los brazos para el aspa y las arandelas de seguridad del lado inferior del motor Si se han instalado soportes de plástico con los tornillos para el brazo para el aspa desechar los soportes de plástico guardar los tornillos para el brazo para el aspa y las arandelas de seguridad para asegurar los brazos para el aspa Alinear los agujeros de uno de los brazos para las aspas con los aguje...

Страница 20: ...onal Apretar la tuerca hexagonal encima de la arandela de seguridad para que se encajen bien Referirse al diagrama 2 Localizar los cables NEGRO o AZUL y BLANCO en la caja de encendido con etiqueta FOR LIGHT para la luz Conectar el cable BLANCO de la caja de encendido al cable BLANCO del conectador para el juego de luz Conectar el cable NEGRO o AZUL de la caja de encendido al cable NEGRO del conect...

Страница 21: ...erca hexagonal arandela de hule 11 Verificación del funcionamiento del ventilador Se le recomienda poner el ventilador a prueba antes de terminar la instalación Regresar la corriente de electricidad en el cortacircuitos y encender el interruptor de la luz en la pared si se aplica Verificar las velocidades del ventilador con la cadena de encendido en la caja de encendido Empezar en estado de APAGAD...

Страница 22: ...MADE garantiza este ventilador al comprador original de grupo familiar para uso interior con las siguientes condiciones GARANTÍA DE 1 AÑO CRAFTMADE reemplazará o reparará cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo manual Comunicarse con el Servicio al cliente de CRAFTMADE al 1 800 486 4892 para acordar el reenvío del ventilador Devolver e...

Отзывы: