page 5
5. Fan Assembly (with downrod). (cont. )
With the hanging bracket secured to the outlet box
and able to support the fan, you are now ready to
hang your fan. Grab the fan firmly with two hands.
Slide downrod through opening in hanging bracket
and let hanging ball rest on the hanging bracket.
Turn the hanging ball slot until it lines up with the
hanging bracket tab.
WARNING
: Failure to align slot in hanging ball with
tab in hanging bracket may result in serious injury or
death.
Tip
: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you once
you are set on the ladder.
hanging ball slot
hanging bracket tab
6. Wiring.
WARNING
: Turn off circuit breakers to current
fixture from breaker panel and be sure switch is
turned to the OFF position.
CAUTION
:
Be sure outlet box is properly grounded
and that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to below, please use a
qualified electrician.
When downrod is secured in place on the
hanging bracket, electrical wiring can be
made as follows:
Connect
BLACK
and
BLUE
wire from fan to
BLACK
wire from ceiling with wire connector
provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together
from fan to
BARE
/
GREEN
wire from ceiling with
wire connector provided.
If you intend to control the fan light with a
separate light switch connect
BLUE
wire from
fan to the
BLACK
supply from the independent
switch.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately).
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
*
from ceiling
from fan
ground
(green or bare)