4. Installation of Wall Bracket. (cont.)

wall
bracket

Attach wires from 4-wire plug to the supply wires 
(from the wall) as follows:

Connect 

GREEN

 wire from 4-wire plug to 

GREEN/BARE 

wire from wall with wire connector provided.
Connect 

BLACK

 wire from 4-wire plug to 

BLACK

 wire 

from wall with wire connector provided. Connect 

WHITE

 

wire from 4-wire plug to 

WHITE

 wire from wall with wire 

connector provied. Connect 

BLUE

 wire from 4-wire plug 

to 

BLUE

 wire from wall with wire connector provided.

stud

stud

1/4"

(6.5mm)

mounting

hole

pilot holes

7 feet
(2.13m)

First determine the approximate position of where you 
want the fan to be located on the wall. [Remember that 
the fan must be mounted at least 7 feet (2.13m) from the 
floor.] 

NOTE

: Ensure there is an electrical source near the 

approximate location, such as an existing outlet box 
or an electrical outlet, as you will need to pull the 
supply wires through the opening in the middle of the 
wall bracket.

You MUST use 

ALL FOUR

 holes in wall bracket when 

installing wall bracket. Position wall bracket on wood 
stud or wood post and mark 4 hole locations. 
 
Drill 4 

pilot holes 

over holes marked onto mounting 

surface. Position wall bracket over pilot holes and install 
screws (provided in hardware pack) into each hole.
  

ALTERNATE CONCRETE WALL INSTALLATION

:

 

Use all 4

 

mounting 1/4" (6.5mm) holes when installing wall bracket 
on a

 

concrete wall. The 3/16 in. (5mm) concrete wall 

anchors necessary for this type of installation are NOT 
provided and

 

must be purchased separately

.

 

Make sure 

that concrete wall anchors can support a total of 80 
lbs.

WARNING

: It is very important you use the proper 

hardware when installing the wall bracket as this will 
support the fan. 

screws

screws

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code (or 
the Canadian Electric Code). If you are unfamiliar with 
electrical wiring or if the house/building wires are different 
colors than those referred to below, please use a qualified 
electrician.

WARNING

:  If using this fan in a DAMP location, this fan 

must be connected to a supply circuit that is protected 
by a Ground Fault Circuit Interrupter (GFCI) to reduce 
the risk of personal injury, electrical shock or death.

5. Wiring.

4-wire

 plug

WHITE

BLACK

BLACK

BLUE

BLUE

WHITE

wire

connector

W

GREEN

GREEN

Содержание Bellows I

Страница 1: ... USE Installation Guide Table of Contents Safety Tips pg 1 Unpacking Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Installation of Wall Bracket pgs 3 4 Wiring pgs 4 5 Installation of Fan pg 6 Wall Control Operation pg 6 Testing Your Fan pg 7 Troubleshooting pg 7 Warranty pg 7 Parts Replacement pg 7 3170356 Bellows I ...

Страница 2: ... and or fire do NOT install fan directly to SheetrockTM drywall fan must first be secured to appropriate size stud or wood beam underneath WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 4 After installation is complete check that ...

Страница 3: ...g Remove items from Styrofoam inserts Remove fan assembly and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety f w wall control b c d e...

Страница 4: ...mounted on an INDOOR wall or on an ENCLOSED porch or ENCLOSED patio wall CAUTION If you are going to attach the fan to a wood stud or wood post the stud or wood post must be wide enough and thick enough to sustain the wall bracket and the weight of the fan ENCLOSED porch or ENCLOSED patio wall installation INDOOR wall installation Turn off circuit breakers to current fixture from breaker panel and...

Страница 5: ...d or wood post and mark 4 hole locations Drill 4 pilot holes over holes marked onto mounting surface Position wall bracket over pilot holes and install screws provided in hardware pack into each hole ALTERNATE CONCRETE WALL INSTALLATION Use all 4 mounting 1 4 6 5mm holes when installing wall bracket on a concrete wall The 3 16 in 5mm concrete wall anchors necessary for this type of installation ar...

Страница 6: ...for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guaran...

Страница 7: ...e fan firmly with two hands Align the 4 slots in the middle of the back of the fan assembly with the 4 hooks on the wall bracket and then pull down firmly on fan assembly WARNING Make sure that all 4 hooks on the wall bracket have engaged completely with the 4 slots in the fan assembly and that the fan assembly is stable Replace set screw at bottom of wall bracket be sure to securely tighten set s...

Страница 8: ... or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Ellington Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade Ellington We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE ELLINGTON will repair or replace at no charge to the o...

Страница 9: ... Preparación para la instalación Pág 3 Instalación de la abrazadera de pared Págs 3 4 Instalación eléctrica Págs 4 5 Instalación del ventilador Pág 6 Operación del control de pared Pág 6 Verificación del funcionamiento del ventilador Pág 7 Localización de fallas Pág 7 Garantía Pág 7 Piezas de repuesto Pág 7 LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA Guía de instalación 3170356 B...

Страница 10: ...e riesgo de incendio y o una descarga eléctrica NO instalar el ventilador directamente en el SheetrockTM o drywall cartón piedra o tablaroca primeramente el ventilador tiene que estar bien sujeto al tamaño correspondiente de entramado o madera que se encuentre debajo de ello ADVERTENCIA Si va a utilizar este ventilador en un lugar HUMEDO hay que conectar el ventilador a un circuito de alimentación...

Страница 11: ...alaje Sacar la unidad del ventilador y ponerlo en una alfombra o en el embalaje para evitar rayar el acabado Guardar la caja de cartón o el empaquetamiento original en caso de que tenga que mandar el ventilador para alguna reparación Comprobar las piezas del ventilador con el inventario de piezas y verificar que se incluyeron todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provista...

Страница 12: ... paleta plano alicates ajustables o llave de tuercas y escalera de tijera Para prevenir daño corporal y otros daños estar seguro de que el lugar en donde va a colgar el ventilador le permite un espacio libre de 2 13m 7 pies entre el piso para prevenir contacto accidental con las aspas Se puede colgar este ventilador solamente en una pared DENTRO DE la casa o un edificio o en un patio CERRADO o en ...

Страница 13: ... las anclas de pared para concreto puedan soportar un total de 36 29 kg 80 lb ADVERTENCIA Es muy importante usar los artículos de ferretería correctos al instalar la abrazadera de pared como esto servirá para apoyar el ventilador entramado tornillos Conectar los cables que salen del enchufe de 4 cables a los cables de alimentación de la pared como sigue Conectar el cable VERDE del enchufe de 4 cab...

Страница 14: ...uario para manejar el equipo NOTA Se han hecho pruebas en este equipo y se ha comprobado que cumple con los límites para un aparato digital de clase B de acuerdo con la Parte 15 de las Reglas de la FCC Se concibieron estos límites para proveer protección razonable contra la interferencia adversa en una instalación residencial Este equipo produce usa y puede radiar energía de radiofrecuencia y si n...

Страница 15: ...io de la parte trasera de la unidad del ventilador con los 4 ganchos en la abrazadera de pared y jalar firmemente hacia abajo en la unidad del ventilador ADVERTENCIA Asegurarse de que los 4 ganchos en la abrazadera de pared se metan completamente en las 4 ranuras de la unidad del ventilador y que la unidad del ventilador esté estable Volver a introducir el tornillo de fijación en la parte inferior...

Страница 16: ...lador al comprador original de grupo familiar para uso en lugares húmedos lo cual se define como dentro de la casa o un edificio en un porche cerrado o un pórtico cerrado con las siguientes condiciones GARANTIA DE 1 AÑO CRAFTMADE ELLINGTON reemplazará o reparará cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo manual Comunicarse con el Servicio...

Отзывы: