Wiring Instructions
NOTE: Use instructions packed with celing fan to wire ceiling fan.
WARNING: To avoid overheating and possible damage to his device and
other equipment, do not install to control a receptacle, fluorescent
lighting, transformer, or motor-operated appliance other than the fans for
which this control is intended. Use this device only with copper or
copper clad wire. With aluminum wire use only devices marked
CO/ALR.
1. Remove insulation to expose 3/4" bare copper wire at end of circuit
conductors. Keep wire ends straight.
2. Connect wires per wiring diagram as follows: black leads (one each)
to black (hot) line, green ground wire to copper outlet wire. Hold
bare ends together. Push wires firmly into wire connector. Screw
connector on clockwise until no bare copper shows. Secure connector
with electrical tape. CAUTION: Never attach white neutral wire to
TCS+ Control
3. Make sure battery is properly installed in switch. The switch should
already have this preinstalled, but double check before installing the
mounting plate (see diagram). Note: The battery replacement code is
23A 12Volt.
4. Mount device with long mounting screws (provided). Install wallplate
and tighten cover screws.
5. Restore power at circuit breaker or fuse. Installation is complete.
Neutral
(White Wire)
Hot Line
(Black Wire)
SINGLE POLE
Neutral
(White Wire)
Load
(Black Wire)
23A 12Volt
Battery
HI
MED
LOW
OFF
L-1
L-2
REV
OFF
ON
12V. BATT.
SUPER
23A 12V
1 2 3 4
ON
Ground Wire
(Copper Wire)
Ground Wire
(Green Wire)
Electrical Connections
CAUTION:
Always turn off power at breaker before attempting any wire
connections.
Fan and lights
controlled by
remote control
unit
Connect black fan wires to black outlet wire. Connect white fan wire to
white outlet wire and green grounding lead wire from the grounding
conductor to the supply circuit (see figure A). Use wire connectors
provided with your fan. No loose strands or loose connections should be
present. Turn splices upward and carefully push all wiring into outlet box.
When wall switches are employed, switches should be UL listed for use
with ceiling fan.
Ground
Black
White
White
Green
Black
Blue
Light Switch
Figure B
Ground
Black
White
Blue
Black
White
Green
Figure A