8.0.2. Excessive Smoke Coming Out of Exhaust Stack
Step
Smoke Coming Out of the Exhaust Stack
1
White smoke indicates that there is too much air being forced though the burner. Loosen the
Air Shutter screw and rotate the Air Shutter counter clockwise to reduce air. Refer to
, for the proper air settings and diagram.
2
Black smoke indicates that there is not enough air being forced through the burner. First
check the air settings, if more air is required rotate Air Shutter clockwise. Refer to
3
Refer to
Fig. 8.3 Diesel Burner Air Settings
to locate the following components. Using a 7/16"
wrench, remove the copper fuel line nut attached to the nozzle line. Next remove the locking
nut for the nozzle tube. Then loosen the locking tabs on the ignition coil and open the ignition
coil. Remove the nozzle line assembly.
4
Fig. 8.2 Diesel Burner Electrode Adjustment
, make sure the electrodes are in the
correct position. Loosen the clamp holding the electrodes in place so they can be adjusted.
Inspect the porcelain ceramic insulator for any cracks. Also check the tip of each of the
electrodes to make sure they still have a sharp point and are not rounded off.
5
If it has been longer than 500 hours since the last time the burner nozzle was replaced,
Crafco recommends replacing the burner nozzle at this time.
6
Reassemble the burner, using the reverse order in Step 3.
7
Remove the burner box assembly by removing the four (4) 1/2" bolts, flat washer, lock
washer, and nuts holding the burner box onto the trailer.
7a
Make sure the insulation inside the burner box is not soaked with diesel fuel.
7b
If the insulation is soaked with diesel fuel, you will need to replace the insulation.
7c
Reassemble the burner box.
8.0.3. Burner Lights but Shuts Down After 15 Seconds
Step
Burner Troubleshooting
1
Remove cord set from fuel solenoid.
2
Check the ohms between the terminals of fuel solenoid.
3
If the reading is between 15-25 ohms the coil is good.
4
If the reading is outside the above range or the meter indicates an open circuit, replace the
fuel solenoid.
Table 8-7 Smoke Coming Out of Exhaust Stack
Table 8-8 Burner Lights But Shuts Down After 15 Seconds
Содержание EZ 500 Series II
Страница 1: ...Parts Manual 26603 Revision K...
Страница 4: ...EZ500 Series II Melter Electric Hose PN 46100EB EZ500 Series II Melter Standard Hose PN 46100SB...
Страница 12: ......
Страница 14: ......
Страница 22: ......
Страница 38: ......
Страница 52: ......
Страница 130: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...2019 Crafco Inc...