2.
Choose Inverter RS485 address
This is the unique Modbus address of the inverter within a network of
inverters and communication devices. The address can be any number
between 0 and 99.
ENTER TO SETUP
2.485Adr: 240
↓
Ent
Esc
or
Ent
ENTER TO ACCEPT
485Adr:240
↕
Figure 4-3 Choose Inverter RS485 address
3.
Choose Inverter Baud rate
Choose the communication Baud rate to match the rate of the device
(gateway) that connects to inverter. The default Baud rate is 9600.
1. Press Up and Down key to change number for each digit.
2. Press Enter key to accept the value for each digit. The display will
automatically jump to the next digit for entry.
3. After the last digit, Enter key will move to the next setting item.
ENTER TO ACCEPT
485bps: xxxx
↕
ENTER TO SETUP
3.485Bps: 9600
↓
Ent
Esc
or
Ent
Figure 4-4 Choose Inverter baud rate
4.
Set Default
INSTRUCTION:
No two Inverters in the same network can share the same address.