35
Figure 4-8 Operation information indication
4.3.4 Alarm
As described before, when faults occur during the normal operation of the
inverter, corresponding fault message will be indicated in “2 Alarm” menu
besides the sound and light alarms. Move the cursor to “2 Alarm” and press
ENT
to check out the specific fault information, as shown in Figure 4-9.
2 Alarm
No Alarm
SPICommErr
IntProtectA
…
If not existed
existed
Figure 4-9 Alarm / failure information
4.3.5 History
Move the cursor to “3 History” in the main interface. Press
ENT
to check
the history information, as shown in Figure 4-
10. There are 4 submenus in “3
History” : “1 ErrRecd”, “2 OP. Recd”, “3 Version” and “4 TotalTag”.
(1) UP to 100 pieces of latest fault messages can be recorded and found
in “1 ErrRecd” menu.
(2) The latest 21 days’ operation history data is available to be found in “2
OP. Recd” menu. All variable names in the data comply with the content in “1
OP. Info” menu of the main interface. The users can select the “2 OP. Recd”
menu and input the retraceable days (For example, the input number is 21. If
the current date is December 15th, the LCD will indicate the operation
information of 21 days before that date which is November 24th).
Содержание SC Series
Страница 1: ...CPS SC Series Grid tied PV Inverter CPS SC20KTL DO US 480 Installation and Operation Manual Ver 1 2 ...
Страница 17: ...15 Figure 3 7a Mounting inverter on the bracket Figure 3 7b Mounting inverter on the bracket Hand Grab ...
Страница 18: ...16 Figure 3 7c Mounting inverter on the bracket Figure 3 7d Mounting inverter on the bracket ...
Страница 30: ...28 Figure 3 21 Diagram of communication wiring ...
Страница 61: ...59 Figure 6 13 Securing panels on both sides ...