CPS BlackMAX VPC Series Скачать руководство пользователя страница 7

OPERATION

7

Vacuum Pump Operation

Vacuum Pump Operation

4. Open manifold valves.

5. Turn vacuum pump power switch 

“ON”

.

6. Run vacuum pump until final vacuum level is met.

-Do not run vacuum pump continuously for more than 2 hours.

7. Once the final vacuum level is reached, close manifold vavles, turn power switch 

“OFF”

.

Vacuum Operation Complete

Routine Maintenance

It is recommended to change the vacuum pump oil after 

25 hours

 of usage. The purity of the 

oil will determine the final vacuum level achieved. Always use the CPS recommended vacuum 

pump oil (

VPOQ 

VPOP

 / 

VPOG

). The oil provided with the pump has been specially blended 

to maintain maximum visosity at normal running temperatures as well as cold weather starts.

OIL CHANGE PROCEDURES:

1. Be sure the pump oil is warmed up. if not warm, turn vacuum pump 

“ON”

 for 

 minutes.

2. Make sure vacuum pump is not plugged in.
3. Remove the oil drain cap and drain the contaminated oil into a suitable container. Tilt 

  the vacuum pump toward the oil drain port.

4. Once  all  the  oil  has  been  drained,  re-secure  the  oil  drain  cap  back  onto  the  oil  drain

 port.

5. Remove the exhaust / oil fill cap and add oil until it is seen in the middle of the oil sight 

  glass. Re-secure exhaust / oil fill cap.

Содержание BlackMAX VPC Series

Страница 1: ...VPC Series 18VDC CORDLESS VACUUM PUMP OPERATION MANUAL ...

Страница 2: ...ign allows for operation under high temperature conditions Rated ultimate vacuum of 100 microns Single Stage 15 microns Two Stage All vacuum pumps allow for multiple connections 1 4 SAE for R 22 and other miscellaneous refrigerants applications 5 16 SAE for R410A and R32 applications Accessible oil drain port sight glass make both oil maintenance and accuracy easy To help you get a good start plea...

Страница 3: ...tery and battery charger information Do not charge damaged batteries Risk of overheating and fire WARNING Do not operate the vacuum pump on systems under pressure Damage to the pump may occur CAUTION All hoses may contain liquid refriger ant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such as safety goggles and glo...

Страница 4: ...7 lbs w battery Operating Temperature Range 0 C 32 F to 52 C 125 F Power Source 18VDC Li on battery 6 0Ah BL18 series compatible Ultimate Vacuum 100 Microns 15 Microns Oil Capacity 9 oz 250 ml 10 oz 300 ml Construction Heavy Gauge Aluminum Chasis with hard reinforced base and rubber lined steel handle Control System ON OFF power switch Free Air Displacement 2 CFM Intake Fittings 1 4 5 16 SAE 45D M...

Страница 5: ...l vacuum pump CPS vacuum pump oil 18VDC Li on 6 0 Ah battery Operational manual Sure Grip Handle Reinforced Base LED Indicator ON OFF Switch Oil Drain Oil Sightglass Inlet Ports 18 Volt DC Li on battery Oil Refill Cap 18 Volt DC Li on battery mount 18 Volt Inlet Solenoid ...

Страница 6: ...l cap and add oil until it is seen in the middle of the oil sight glass Re secure cap 3 Remove the 1 4 inlet service port cap turn on the vacuum pump After 15 seconds replace 1 4 cap back on inlet port 4 Re check vacuum pump oil level Add or remove oil if necessary To achieve good final vacuum levels the oil level should be visually seen through sight glass CAUTION DO NOT RUN THIS EQUIPMENT WITH L...

Страница 7: ...se the CPS recommended vacuum pump oil VPOQ VPOP VPOG The oil provided with the pump has been specially blended to maintain maximum visosity at normal running temperatures as well as cold weather starts OIL CHANGE PROCEDURES 1 Be sure the pump oil is warmed up if not warm turn vacuum pump ON for 5 minutes 2 Make sure vacuum pump is not plugged in 3 Remove the oil drain cap and drain the contaminat...

Страница 8: ...anufacturing and material defects to the original owner for one year from the date of purchase If the equipment should fail during the guarantee period it will be repaired or replaced at our option at no charge This guarantee does not apply to equipment that has been altered misused or solely in need of field service maintenance All repaired equipment will carry an independent 90 day warranty This...

Отзывы: