The appliance and its individual shutoff valve (to be supplied by user) must be disconnected from

 

the gas supply piping system during any pressure testing of that system at test pressures in excess

 

of 1/2 PSI (3.45 kPa).

•  The

 appliance must be isolated from the gas supply piping system by closing its individual manual 

shut-off valve during any pressure testing of the gas supply piping system at test pressures equal

 

to or less than 1 / 2 PSI (3.45 kPa) 

CAUTION: 

•  Failure to comply with the following operation instructions could lead to potential hazards and/or unsafe

 

  practice and could result in injury and damage to product and property. 

NOTICE: 

  Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,

 

  Inc., states in its NFPA96 latest edition that local codes are "Authority Having Jurisdiction" when it comes to

 

  requirement for installation of equipment. Therefore, installation should comply with all local codes.

  This product is intended for commercial use only. Not for residential use. 

WARNING:

• 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other equipment.

 

  Improper installation, adjustment, alteration, service or maintenance could lead to property damage, injury or

 

  death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing

 

  CPG equipment. This manual must be retained for future reference.

•  A factory authorized agent must handle all maintenance and repair.

Safety Precautions

Gas Pressure

Содержание 351WOKR13L

Страница 1: ...User Manual 351WOKR13 L N Cooking Performance Group www cookingperformancegroup com Gas Powered Wok Ranges 12 2021...

Страница 2: ...sers do not follow the instructions or guidelines stated here The 351WOKR13N L features a durable stainless steel construction with 4 adjustable legs It is equipped with a powerful 18 tip duck jet bur...

Страница 3: ...E Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisd...

Страница 4: ...Dimensions 18 x 23 x 23 Net Weight 70 lb Gross Weight 88 lb of Burners 1 Gas Type Liquid Propane Natural Gas Intake Tube Pressure 10 W C 5 W C BTU per Burner 95 000 BTU BTU Total 95 000 BTU Orifice N...

Страница 5: ...on the appliance prior to connecting the equipment to the gas line Failure to install a regulator could be potentially hazardous and will void the appliance warranty See Pressure Regulator on pg 6 for...

Страница 6: ...e factory for 5 WC natural gas or 10 WC liquid propane gas depending on customer s ordering instructions Prior to connecting the regulator check the incoming line pressure as these regulators can only...

Страница 7: ...ect possible problems caused by rough handling or vibration during shipment and are to be performed only by qualified service personnel These adjustments are the responsibility of the customer and or...

Страница 8: ...and maintenance of this equipment must be carried out by a qualified technician All installation must be carried out according to the law Cooking Performance Group is not responsible for damages due...

Страница 9: ...le Chemical Blast 8 Pull catch tray from front body wipe away residue and clean with mild detergent 1 All stainless steel body parts should be wiped regularly with hot soapy water during the day and w...

Страница 10: ...Adjust height of pilot Inconsistent burning Insufficient gas pressure in pipe Contact local gas supply department Nozzle occlusion Adjust nozzle diameter Flow of connection pipe is not adequate Increa...

Отзывы: