REVISED 11/2021
Floor
Fryers
Cooking Performance Group
.
www.cookingperformancegroup.com
User Manual
351FFOP40N, 351FFOP40L, 351FFOP50N, 351FFOP50L
5005951
Страница 1: ...REVISED 11 2021 Floor Fryers Cooking Performance Group www cookingperformancegroup com User Manual 351FFOP40N 351FFOP40L 351FFOP50N 351FFOP50L 5005951...
Страница 2: ...he event users do not follow the instructions or guidelines stated here CPG floor fryers feature an open pot design that makes heat transfer reliable and efficient for optimal performance Range match...
Страница 3: ...or other flammable vapors and liquids in the vicinity of this or any other equipment Improper installation adjustment alteration service or maintenance could lead to property damage injury or death Re...
Страница 4: ...he unit is installed and working properly All propane LP gas fryers MUST HAVE an appliance regulator installed in addition to the tank or stage regulator If propane fryer is installed without the corr...
Страница 5: ...or raise each corner of the fryer 5 Attach restraints as required by local codes FLUE INSTALLATION 1 Unpack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two se...
Страница 6: ...ons for adequate air supply must also be provided DO NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilation system according...
Страница 7: ...B149 2 as applicable An adequate gas supply is imperative Undersized or low pressure lines will restrict the volume of gas necessary for satisfactory performance A combination gas valve and pressure...
Страница 8: ...t any damage or distortion to the internal piping and controls of the unit WARNING Checking for gas leaks Using a gas leak detector or a soapy water solution is recommended for locating gas leaks Matc...
Страница 9: ...become red hot burn the solid shortening weaken the fry pot and could result in fire CAUTION Never attempt to melt a solid block of shortening on the top of the heat tubes Never start the burners whe...
Страница 10: ...pilot flame When the pilot flame goes out generation of current ceases and the valve closes automatically HIGH LIMIT CONTROL CPG Floor Fryers are equipped with a secondary heat control that prevents t...
Страница 11: ...d oil or shortening to MIN oil level mark on rear of fry pot 8 To resume cooking turn the combination gas valve knob to ON position WEEKLY 1 Follow steps 1 through 4 of the Daily cleaning procedure se...
Страница 12: ...aused by thickening of the protective surface of the stainless steel and are not harmful Heat tint can normally be removed by the above cleaning techniques but tint which does not respond to that proc...
Страница 13: ...e knob to the PILOT setting 2 Remove pressure tap plug from burner manifold located directly below the burners in the cabinet 3 Install a fitting appropriate to connect a manometer 4 Turn combination...
Страница 14: ...or temperature to stabilize or until several temperature readings are identical 3 Recalibrate if setting and actual temperature differ by more than 10 F 4 Remove dial from dial shaft B Be careful that...
Страница 15: ...low the lighting instructions on pg 9 2 Turn on gas supply for the unit 3 Replace thermopile To be installed by professional 4 Carefully clean the thermopile connections 5 Clean or replace clogged ori...
Страница 16: ...www cookingperformancegroup com 16 User Manual Wiring Diagram...