background image

www.CookingPerformanceGroup.com

 

1-800-678-5517

USER MANUAL

 OPERATING INSTRUCTIONS

• 

Operation of this equipment must be performed by qualified or authorized personnel who have read 
and are familiar with the functions of the equipment. 
 

• 

To perform maintenance and repairs of the appliance, please contact the factory, factory representative, or 
the nearest authorized local service company to get proper repairs. 
 

• 

Information on this plate includes the model, serial number, BTU/hour input of the burners, operating 
gas pressure in inches WC, and whether the appliance is fitted for natural gas or liquid propane. When 
communicating with the factory about a unit or requesting special parts or information, rating plate 
data is essential for proper identification. 
 
 
 
 
 
 
 

• 

The appliance area must be kept free and clear of all combustible materials, and placed horizontally 
on a non-skid surface.  
 
 
 
 
 
 
 

• 

The area in front of, around and above the appliance must be kept clear to avoid any obstruction of the flow 
of combustion and ventilation air.

• 

Adequate clearance must be maintained around the appliance for easy servicing.

• 

Provisions should be made for any commercial, heavy duty cooking appliance to have it its exhaust 
combustion waste products released to the outside of the building. The usual practice is to place the 
appliance under an exhaust hood, which should be constructed in accordance with local codes.

• 

Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in the 
room and / or cause air drafts, either of which can interfere with the pilot or burner performance and could 
be difficult to diagnose. Air movement should be checked during installation. Air openings or baffles may 
have to be provided in the room, if pilot or burner outrage problem persists.

MAINTENANCE

RATING PLATE

CLEARANCES

COOKING PERFORMANCE GROUP

COOKING APPLIANCES MUST BE 

CONNECTED ONLY TO THE TYPE OF GAS 

IDENTIFIED ON THE RATING PLATE

Gas Stock Pot Range

Item: 

351CPGSPR18N 

Model: 

ATSP-18-1

Gas Type: 

Natural   

BTU:

 80,000

Orifice Size: 

3/4“   

Manifold Pressure: 

4” WC

 

Max Pressure: 

14” WC

Serial #:

Lancaster, PA

Conforms to ANSI Z83.11-2016

Certified to CSA1.8-2016

Gas Food Service Equipment

MADE IN CHINA

Intended for other than household use.

4003027

CPG MODEL

Non-Combustible

Rear

Sides

Bottom

CPGSPR18L - Stock Pot Range

6”

6”

6”

CPGSPR18N - Stock Pot Range

6”

6”

6”

AIR SUPPLY & VENTILATION

All manuals and user guides at all-guides.com

Содержание 351CPGSPR18L

Страница 1: ...USER MANUAL Stock Pot Range MODEL 351CPGSPR18 L N 06 2017 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ... unit in compliance with this manual Any nearby walls surfaces kitchen supplies etc should be non combustible and heat resistant Please pay special attention to fire prevention regulations This user s manual contains information and guidelines collected from years of industry experience For optimal safety and efficient operation please make this document available to staff members authorized to us...

Страница 3: ...supplied must be installed on the appliance prior to connecting the equipment to the gas line Failure to install a regulator could be potentially hazardous and will void the appliance warranty The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45kpa The appliance must...

Страница 4: ...hould be made for any commercial heavy duty cooking appliance to have it its exhaust combustion waste products released to the outside of the building The usual practice is to place the appliance under an exhaust hood which should be constructed in accordance with local codes Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in the room and or c...

Страница 5: ...ill have inlet outlet openings and are adjusted at the factory for 4 WC natural gas or 10 WC liquid propane gas depending on customer s ordering instructions Prior to connecting the regulator check the incoming line pressure as these regulators can only withstand a maximum pressure of psi 14 WC If the line pressure is beyond this limit a step down regulator will be required The arrow shown on the ...

Страница 6: ... minute for existing gas in pipe to disperse and try again after 1 minute Turn ON gas valve s to light the main burner For complete shutdown shut OFF gas valve s and turn pilot valve s by adjusting the screw clockwise to shut off gas to the pilot s Wait 5 minutes before next use Turn off range remove all objects and disconnect energy source Remove control panel cooking grates pilot light head and ...

Страница 7: ...NOT USE steel wool abrasive cloths or powders to clean stainless surfaces If it is necessary to scrape stainless steel to remove encrusted materials soak in hot water to loosen the material then use a wood or nylon scraper DO NOT USE a metal knife spatula or any other metal tool to scrape stainless steel Scratches are nearly impossible to remove Ensure your Cooking Performance Group range is check...

Страница 8: ...stent burning Insufficient gas pressure in pipe Contact local gas supply department Nozzle does not match gas requirements Adjust nozzle diameter Flow of connection pipe is not adequate Increase pipe s allowable flow Damper opening degree is too large Adjust damper Yellow flame and or black smoke Incorrect gas Change gas Nozzle does not match gas requirements Adjust nozzle diameter Not enough air ...

Страница 9: ...WEIGHT 120 0 Lb 120 0 Lb OF BURNERS 2 2 GAS TYPE Liquid Propane Natural Gas INTAKE TUBE PRESSURE 4 WC 10 WC BTU PER BURNER 40 000 40 000 BTU TOTAL 80 000 80 000 NOZZLE NO LP49 NG32 IGNITION TYPE Manual Manual VALVE TYPES Pilot Light Pilot Light TEMPERATURE CONTROL None None TOP GRADE DIMENSIONS 17 9 x 20 9 17 9 x 20 9 SPECIFICATIONS MAY VARY DEPENDING ON MODEL AND ARE SUBJECT TO CHANGE AT ANY TIME...

Страница 10: ...10 www CookingPerformanceGroup com 1 800 678 5517 USER MANUAL EXPLODED VIEW All manuals and user guides at all guides com ...

Страница 11: ...01990006 Damper cover 2 15 301081011 Stainless steel cross screws 2 16 301080007 Brass nut 0 17 301070011 Brass hoop 0 18 301050015 Brass street elbow 0 19 21106002013 Front burner outer pilot intake tube 1 20 301060003 Pilot light head 2 21 211060000000 Pilot light head stator 2 22 21106002014 Front burner inner pilot intake tube 1 23 301080008 Brass lock nut 0 24 301050014 Brass double male elbo...

Страница 12: ...ersonnel or changed from our original design is not covered under this Warranty Furthermore COOKING PERFORMANCE GROUP assumes no obligation for any product which has been subject to misuse abuse or harsh chemicals Normal maintenance as outlined in the instructions is the responsibility of the owner user and is not a part of this warranty Ninety days on Cast Iron Parts Light bulbs porcelain and gla...

Страница 13: ...www CookingPerformanceGroup com 13 1 800 678 5517 USER MANUAL NOTES All manuals and user guides at all guides com ...

Отзывы: