Troubleshooting
18 Rev
42011-20090428
Troubleshooting
Problem
Cause
Solution
Generator will not start
No fuel
Add fuel
Faulty spark plug
Replace spark plug
Unit loaded during start up
Remove load from unit
Generator will not start;
Generator starts but runs roughly
Choke in the wrong position.
Adjust choke.
Spark plug wire loose
Attach wire to spark plug
Out of fuel
Fill fuel tank
Generator shuts down during
operation
Low fuel level
Fill fuel tank
Generator is overloaded
Review load and adjust. See “Power
Management”
Generator cannot supply enough
power or overheating
Insufficient ventilation
Check for air restriction. Move to a
well ventilated area
Cable not properly connected
Check all connections
No AC output
Connected device is defective
Replace defective device
Circuit breaker is open
Reset circuit breaker
Capacitor defective
Replace capacitor (Service Center)
Faulty brush assembly
Replace brush assembly (Service
Center)
Faulty AVR
Replace AVR (Service Center)
Loose wiring
Inspect and tighten wiring
connections
Other
Contact the help line.
Engine governor defective
Contact the help line
Generator gallops
Overload
Review load and adjust. See “Power
Management”
Repeated circuit breaker tripping
Faulty cords or device
Check for damaged, bare or frayed
wires. Replace defective device