CPE 2 STROKE GENERATOR Скачать руководство пользователя страница 13

  

Operation 

Rev 42011-20090428

 

 

9

 

Do Not Overload Generator

 

Capacity

 

Follow these simple steps to calculate the 

running and starting watts necessary for 

your purposes.  

1.

 

Select the electrical devices you plan on 

running at the same time. 

2.

 

Total the running watts of these items. 
This is the amount of power you need to 

keep your items running. 

3.

 

Identify the highest starting wattage of 
all devices identified in step 1. Add this 

number to the number calculated in step 
2. Surge wattage is the extra burst of 

power needed to start some electric 

driven equipment. Following the steps 
listed under “Power Management” will 

guarantee that only one device will be 

starting at a time. 

Power Management 

Use the following formula to convert voltage 

and amperage to watts: 

 

Volts x Amps = Watts 

 

To prolong the life of your generator and 

attached devices, follow these steps to add 
electrical load: 

1.

 

Start the generator with no electrical 
load attached. 

2.

 

Allow the engine to run for several 

minutes to stabilize. 

3.

 

Plug in and turn on the first item. It is 

best to attach the item with the largest 

load first. 

4.

 

Allow the engine to stabilize. 

5.

 

Plug in and turn on the next item. 

6.

 

Allow the engine to stabilize. 

7.

 

Repeat steps 5-6 for each additional 

item. 

  NOTE 

Never exceed the generator capacity when 
adding loads.  
 

Wattage Reference Chart

 

Use the chart to determine approximate 

wattage requirements for your equipment.  
 

  NOTE 

Starting watts can exceed three times the 
running watts. The values in the following table 
are approximate. Refer to your tool or appliance 
for actual wattage consumption.  

 
 

Item 

Running 

Watts 

Starting 

Watts 

Essentials 

Light Bulb 100W 

100    

Refrigerator/Freezer 1200 

2400 

Freezer 500 

500 

Sump Pump 

600 

1800 

Well Pump 1 HP 

2000 

4000 

Water Heater 

4000    

Security System 

180    

AM/FM Radio 

300    

Garage Door Opener 1/2 HP 

500 

600 

Battery Charger 12V DC 

110    

Heating/Cooling 

Air Conditioner 12000 BTU 

1700 

2500 

Fan 300 

600 

Furnace Fan 1/3 HP 

1200 

2000 

Home Appliances 

Microwave 1000W 

1000    

Electric Range - One Element 

1500    

Electric Skillet 

1250    

Coffee Maker 

1500    

Clothes Washer 

1200    

Entertainment 

CD/DVD Player 

100    

VCR 100 

 

 

Stereo Receiver 

450    

Television 27" 

500    

PC with 15" Monitor 

800    

Job Site 

Belt Sander 3" 

1000 

1500 

Bench Grinder 6" 

700 

1500 

Circular Saw 

1500 

1500 

Compressor 1 1/2 HP 

2500 

2500 

Edge Trimmer 

500 

500 

Hand Drill 1/2" 

1000 

1000 

Lawn Mower 

1200 

1800 

Paint Sprayer 

600 

1200 

Table Saw 

2000 

2000 

 

Содержание 2 STROKE GENERATOR

Страница 1: ...Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 1000 Peak Watts 800 Running Watts 2 STROKE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual Owner...

Страница 2: ......

Страница 3: ...nce Chart 9 Maintenance 10 Engine Maintenance 10 Spark Plugs 10 Air Filter 10 Cleaning 11 Adjustments 11 Maintenance Schedule 11 Generator Maintenance 11 Storage 12 Engine Storage 12 Generator Storage...

Страница 4: ......

Страница 5: ...equipment Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits ple...

Страница 6: ...minently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serio...

Страница 7: ...ting parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produce...

Страница 8: ...ay from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Unintention...

Страница 9: ...ulations 2 12V DC Outlet and Circuit breaker 3 AC Outlet 4 AC Circuit Breaker 5 On Off Switch Flip switch to the On position to start the generator Flip to the Off position to turn off the generator 6...

Страница 10: ...ontrols and Features 6 Rev 42011 20090428 Parts Included Your 42011 Two Stroke Gasoline Powered Generator ships with the following parts 3 Charging Cord Spark Plug Socket 1 piece Handle Assembly 1 set...

Страница 11: ...h regular fuel with a minimum octane rating of 85 and 2 stroke engine oil mixture 5 Fuel Oil ratio of 50 1 1 Gallon fuel 2 5oz 2 stroke engine oil 6 Slowly add fuel oil mixture to the tank DO NOT over...

Страница 12: ...suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power Supply UPS device Most UPS de...

Страница 13: ...the engine to stabilize 5 Plug in and turn on the next item 6 Allow the engine to stabilize 7 Repeat steps 5 6 for each additional item NOTE Never exceed the generator capacity when adding loads Watt...

Страница 14: ...plug 2 Use the spark plug tool that shipped with your generator to remove the plug 3 Inspect the electrode on the plug It must be clean and not worn to produce the spark required for ignition 4 Make...

Страница 15: ...erator Maintenance Make certain that the generator is kept clean and stored properly Only operate the unit on a flat level surface in a clean dry operating environment DO NOT expose the unit to extrem...

Страница 16: ...ely from the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Remove the spark plug and pour about ounce of oil into the cylinder Crank the engine slow...

Страница 17: ...pacity is 0 9 gallons 3 4L Use fuel oil mixture regular unleaded gasoline with a minimum octane rating of 85 mixed with 2 stroke engine oil at ratio of 50 1 1 gallon fuel 2 50z of oil Spark Plugs Your...

Страница 18: ...Specifications 14 Rev 42011 20090428 Parts Diagram...

Страница 19: ...Amp Circuit Breaker 1 24 CT950 02000002 End Cover 1 25 CT950 02000004 Screw M6 80 3 26 GB93 LW 6 Lock Washer 6 3 27 GB90 W 6 Washer 6 3 28 CT950 02000005 Bottom Rubber 4 29 CT950 02000003 Screw M8 15...

Страница 20: ...Number Description Qty 52 GB1667 S4 2 9 5 Screw ST4 2 9 5 4 53 CT950B 05000005 Control Box Cover 1 54 ST02FD 05302007 8 8 Amp Circuit Breaker 1 55 ST168FD 1121100 C Engine Switch 1 56 CT950 02000001...

Страница 21: ...Specifications Rev 42011 20090428 17 Wiring Diagram...

Страница 22: ...ough power or overheating Insufficient ventilation Check for air restriction Move to a well ventilated area Cable not properly connected Check all connections No AC output Connected device is defectiv...

Страница 23: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...

Страница 24: ...ect to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRANT...

Страница 25: ...y Period Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replace...

Страница 26: ...the product on which it is installed along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Ch...

Страница 27: ...Notes Rev 42011 20090428 23 Notes...