CPAT FLEX DSG1 Скачать руководство пользователя страница 1

v 1.1 / 2014.06.12

CPAT FLEX Operation Manual (DSG1)

© 2014 Effigis. All rights reserved. 006-000038-102

Содержание FLEX DSG1

Страница 1: ...v 1 1 2014 06 12 CPAT FLEX Operation Manual DSG1 2014 Effigis All rights reserved 006 000038 102...

Страница 2: ...reflected in a subsequent revision Effigis assumes no responsibility for any omissions or errors that may appear in this document or for any dam ages that may result from the use of information contai...

Страница 3: ...ent Rack 9 3 2 Connecting RF Outputs 9 3 3 Electrical Installation 10 3 4 Internet Connection optional 10 4 Setup 11 4 1 Determining Frequencies and Output Levels 11 4 2 Set Parameters Remotely 12 4 2...

Страница 4: ...date 18 7 2 Manual System Recovery 18 8 Remote Troubleshooting 18 Appendix A Specifications 19 A 1 System 19 A 2 Physical 19 Appendix B Our Services 20 B 1 System 20 B 1 1 Equipment Return Instruction...

Страница 5: ...aution may cause personal injury or damage to the unit Note Indicates additional information about the product 1 3 Certifications This section describes the certifications the DSG1 complies with IN PR...

Страница 6: ...operate this equipment 1 4 Technical Support Effigis Technical Support Service is available from Monday through Friday from 9 00 AM to 5 00 PM Eastern Time Toll free from U S and Canada 1 888 495 657...

Страница 7: ...d signal combiner One output is used per carrier The global operating status is shown on the LCD display located on the DSG1 s front panel Once installed this unit requires no further mechanical setup...

Страница 8: ...e lost or damaged you can order a replacement for the DSG1 Please quote the following part numbers when placing an order Part No Accessory Description 1 5515 DSG1 AC DC adapter 2 5516 DSG1 Operation M...

Страница 9: ...entilation 3 2 Connecting RF Outputs The RF outputs should be connected directly into the cable network s RF forward combiners CAUTION In order to avoid unwanted interference with the QAMs in the cabl...

Страница 10: ...mmunicate with the CPAT FTP server and obtain its param eters and update files you must have the following DHCP enabled on the network The DSG1 s IPv4 address is acquired through dynamic host configur...

Страница 11: ...s 1 Yes 2 No NOTE When changing the frequencies on the DSG1 and DRV3 make sure that you use the appropriate antenna on the DRV3 units to match the selected frequencies 4 1 Determining Frequencies and...

Страница 12: ...aded by the DSG1 4 3 Set parameters using the DSG1 settings application 4 3 1 Download and install the application The DSG1 settings application is a standalone WinForms desktop application named DSG1...

Страница 13: ...G1 found is selected by default To select a dif ferent DSG1 choose another DSG1 from the dropdown menu next to the DSG1 button If no DSG1 units are found the system displays a special message No DSG1...

Страница 14: ...will be lost after a reboot of the DSG1 and the default settings will be applied until you edit them again A Refresh button is available between the two outputs in the Monitoring panel to perform a ne...

Страница 15: ...nd transmission activation and startup PRN These settings are effective immediately and they become the new default settings for the next startup NOTE The DSG1 will always try to connect to the CPAT F...

Страница 16: ...s working normally When flashing RED an error has occurred The LCD screen provides information about the unit It scrolls through the settings to display the following information Output frequencies fo...

Страница 17: ...5 4 1 Normal Shutdown In normal running mode press the front panel ON OFF push button for 1 second then let the DSG1 shut down each process properly A message will then appear on the front LCD screen...

Страница 18: ...ally obtaining its firmware when needed via updates provided from the CPAT FTP server 7 1 Automatic Update The DSG1 device is usually automatically updated when needed The updates are distributed from...

Страница 19: ...cy stability Mid band 1 kHz LTE band 5 kHz Tuning resolution 1 kHz Modulated signal AM 3 to 110 Hz Output level from each RF output from 10 to 50 dBmV Status display Through an LCD on front panel Comm...

Страница 20: ...ation to accompany your equipment For each piece of equipment returned for repair attach a tag that includes the following information Owner s name address and telephone number The serial number produ...

Страница 21: ...licensor of the product B 2 2 Software Effigis warrants to the Customer that new Effigis branded software and firmware will perform in substantial conformance to program specifications for a period of...

Страница 22: ...credit to Customer for the amounts paid for the Product in exchange for return of the nonconforming Product in which case Customer s licenses to any Firmware shall be automatically revoked Customer he...

Страница 23: ...effigis com 23 Operation Manual...

Страница 24: ...effigis com 1 888 495 6577...