Rev 3.0 Cod. 00.008.255
8
ENGLISH
FRONTAL PANEL DESCRIPTION
1
.
Display
LCD 8 x 2 backlight
2.Green
Led:
▪
fix
=
PUMP ON
▪
blinking
= PUMP IN ALARM
3.Red
Led: indicates the injections
4.CAL
button :
▪
allows to enter in programming
▪
saves the changes
5/6.
–
and
+
buttons :
▪
allows to
navigate through the menu
▪
Modify the parameters values
7. ESC/SBY
button
: ▪
puts the pump in stand_by mode
▪
allows to exit the menu
GENERAL FUNCTIONS OF THE PUMP :
-
4 LANGUAGES MENU
: ITALIAN, ENGLISH, FRENCH, SPANISH
- 3 POSSIBLE TYPES OF FUNCTIONING: MANUAL, ON/OFF, PROPORTIONAL
-
ALARM TIME
OF OVERDOSAGE
- START UP
DELAY
-
DEFAULT
PARAMETER
RESTORING
- WATER
FLOW
CONTROL
-
LEVEL
CONTROL
- STOP DOSING (
STAND_BY
)
- REAL TIME FLOW RATE %
DEFAULT SETTINGS
FUNCTIONING:
ON-OFF
SETPOINT:
1.20 ppM
DIRECTION DOSING:
Chlorination
INJECTION FREQUENCY:
100%(150 imp/min)
ALARM TIME:
0unit (disabled)
START UP DELAY:
0 minutes
DEFAULT SETTINGS RESTORE
Push and quickly release
CAL
button and then pressing
+
and
–
buttons
select “
Restore Enter
”
Push
CAL
to confirm the choice. The pump goes back in measure
restoring in memory
the default settings and calibrations parameters.
PUMP’S CONNECTION
A -
è il cavo di alimentazione elettrica , 230 V- 50Hz (a richiesta 115 ~).
B -
è il connettore della sonda di livello (contatti 3 e 4).
OPTIONAL
C -
è il connettore del sensore di flusso (contatti 3 e 4).
OPTIONAL
D -
è il connettore BNC della sonda cloro
E
-
è l’interruttore ON_OFF.
OPTIONAL