background image

LIMITED WARRANTY

The Louisville Tin & Stove Co. warrants to 

the original user the accompanying product for the 
period specified herein, provided said product is 
installed, operated, maintained, serviced, and used 
according to the instructions and specifications 
accompanying the product.   

AS OUTLINED IN 

OUR INSTRUCTIONS, ANY WARRANTY 
CONSIDERATIONS ARE CONTINGENT ON 
INSTALLATION BY A QUALIFIED 
INSTALLER (CONTRACTOR).  SELF-
INSTALLATION IS PROHIBITED AND WILL 
INVALIDATE YOUR WARRANTY. 
 

If within a period of one year from the date 

of installation of the product, any part supplied by the 
manufacturer proves to be defective due to 
workmanship or material, it will replace such part, 
provided parts have not been subjected to misuse, 
alteration, neglect, or accidents.  The term of the 
warranty for the heat exchanger and burners is covered 
in Table A below.  Any claim not made within ten 
(10) days after the expiration of the warranty period 
shall be deemed waived by the user. 
 

The manufacturer shall have no liability or 

be required to perform any obligation under this 
warranty unless, when requested, the user returns, at 
the user’s expense, the component or product claimed 
defective, to the manufacturer for inspection, to enable 
the manufacturer to determine if the claimed defect is 
covered by this warranty. 
 

No charges for freight, labor or other 

expenses incurred in the repair, removal, or 
replacement of any product or component claimed to 
be defective, will be paid by the manufacturer to the 
user, and the manufacturer will not be liable for any 
expenses incurred, by the user, in remedying any 
defect in the product. 
 

Service under this warranty is the 

responsibility of the installer.  In the event service 
under this warranty is needed, the user of the product 

shall request such service directly from the installer.  
If the user is unable to locate the installer, the  user  
should write directly  to  the manufacturer, and the 
name of an alternative service source will be supplied. 
 

The product safety registration card (packed 

inside the appliance) must be completed and returned 
to the factory. 
 

THIS WARRANTY IS EXPRESSLY IN 

LIEU OF ANY OTHER WARRANTIES, EXPRESS 
OR IMPLIED (WHETHER WRITTEN OR ORAL).  
ANY IMPLIED WARRANTY OF 
MERCHANTABILITY OR OF FITNESS FOR A 
PARTICULAR PURPOSE IS EXPRESSLY 
LIMITED TO THE DURATION OF THE 
MANUFACTURER’S EXPRESS, WRITTEN 
WARRANTY. 
 

UNDER NO CIRCUMSTANCES SHALL 

THE MANUFACTURER BE LIABLE FOR ANY 
SPECIAL, INDIRECT OR CONSEQUENTIAL 
DAMAGES OR EXPENSES ARISING DIRECTLY 
OR INDIRECTLY FROM ANY COMPONENT OR 
FROM THE USE THEREOF.  THE REMEDIES SET 
FORTH HEREIN SHALL BE THE EXCLUSIVE 
REMEDIES AVAILABLE TO THE USER AND 
ARE IN LIEU OF ALL OTHER REMEDIES. 
 

SOME STATES DO NOT ALLOW 

LIMITATIONS ON HOW LONG AN IMPLIED 
WARRANTY LASTS, SO THE ABOVE 
LIMITATIONS MAY NOT APPLY TO YOU. 
 

SOME STATES DO NOT ALLOW THE 

EXCLUSION OR LIMITATION OF INCIDENTAL 
OR CONSEQUENTIAL DAMAGES, SO THE 
ABOVE LIMITATIONS OR EXCLUSIONS MAY 
NOT APPLY TO YOU. 
 

THIS WARRANTY GIVES YOU 

SPECIFIC LEGAL RIGHTS, AND YOU MAY 
ALSO HAVE OTHER RIGHTS, WHICH VARY, 
FROM STATE TO STATE. 

 
 
 

 
 
 

 
 

 
 
 

 
 

 

LOUISVILLE TIN & STOVE COMPANY 

737 S. 13

TH

 STREET  -  LOUISVILLE, KY. 40210 

TABLE A 

 

 

 

 

 

 

 

 

          

Warranty Period 

Product   

 

 

 

 

 Heat 

Exchanger/Tubes Burners 

Cozy Gas Fired Floor Furnace 

 

 

 

 

10 Years   

10 Years 

Cozy 

Gas 

Fired 

Wall 

Furnace 

     10 

Years 

 10 

Years 

Cozy Gas Fired Vented Console Heater  

 

 

 

10 Years   

10 Years 

Cozy Gas Fired Direct Vent Heater 

 

 

 

 

10 Years   

10 Years 

Cozy Gas Fired Counterflow Furnace   

 

 

 

10 Years   

10 Years 

Cozy Gas Fired Counterflow Direct Vent Furnace 

 

 

10 Years   

10 Years 

Cozy Gas Fired Mobile Home Direct Vent Furnace 

 

 

10 Years   

10 Years 

Cozy Gas Fired Hi-Efficient Direct Vent Wall Furnace 

 

 

10 Years   

10 Years 

Cozy Gas Fired Direct Vent Baseboard Heater 

 

 

 

10 Years   

10 Years 

Cozy Fan-Type, Direct Vent Through-The-Wall Gas Heater 

 

10 Years   

10 Years 

Cozy Blue Flame Vent Free Heater 

 

 

 

 

N/A 

 

10 Years 

Cozy Infra-Red Vent Free Heater 

 

 

 

 

N/A 

 

N/A 

Содержание W255F and

Страница 1: ...on of this furnace when not connected to a properly installed and maintained venting system can result in Carbon Monoxide C O poisoning and possible death For your safety this furnace and the venting system should be inspected at least annually by a qualified service technician This appliance is equipped with a blocked flue switch designed to protect against a blocked flue condition Thecoatingsele...

Страница 2: ...ER SPECIFICATIONS Your vented wall furnace comes packed in a single carton For wall thermostat models that includes the thermostat thermostat wire and insulated staples Before installing the wall furnace check the rating plate to verify that the Model Number is correct and that the wall furnace is equipped for the type gas you intend to use CONTENTS Page 2 Introduction 2 Lighting Instructions 11 S...

Страница 3: ...DIRECTLYon carpeting tile or any combustible material other than wood flooring the heater shall be installed on a metal or wood panel secured to the floor extending the full width and depth of the heater H Installation and repair must be done by a qualified installer or service technician The wall furnace must be inspected before use and at least annually by a Page 3 1 CONTROLS All controls are pr...

Страница 4: ...donewithin12inchesofthefloor Theseopeningsshallcommunicatedirectly withtheoutdoors orspacesthatcommunicatefreelywiththeoutdoors suchasaventilatedatticandcrawlspace through galvanized or equivalent corrosion resistant ducts Exception unobstructed stud and joist spaces are acceptable ducts provided that not more than one fire block is removed Special provisions must be taken to insurethatthesestudan...

Страница 5: ...of attic Outlet Air Inlet Air Duct Ends 1 ft 300mm above floor FIGURE C FIGUREB ALLCOMBUSTIONAIRFROM OUTDOORS INLETAIRFROM VENTILATEDCRAWLSPACEAND OUTLETAIRTOVENTILATEDATTIC ULListed Vent Cap ULListed Gas Vent Ventilation Louvers each end of attic Outlet Air Inlet Air Ventilation louvers for unheated crawl space Page 5 ALLCOMBUSTIONAIRFROM ADJACENTINDOORSPACES THROUGHINDOORCOMBUSTION AIROPENINGS U...

Страница 6: ...forlocationofthemanualresetblocked flue switch To reset the switch insert a slender rigid object i e screwdriver through the front panel louvers and push the reset button down See Figure B 1 However you may have toremovethefrontpanel thenresettheswitchandreinstallthe front panel to relight heater If homeowner experiences this problem the vent system must be checked and corrected NOTE A pre existin...

Страница 7: ...ightofleftstudthroughfloor plate See Figure 1 located on Page 7 Page 7 FIGURE C Installation of B W Gas Vent for one story buildings or for first floor of multi story buildings Ceiling plate spacers to center B W gas vent in stud space nail securely at both ends Plate cut away for full width of stud space to provide ventilation Studs on 16 inch centers Sheet metal screw base plate to header Use ma...

Страница 8: ...level of multi story buildings Firestop spacers supplied by manufacturer of B W gas vent Plate cut away to provide passage of B W gas vent Nail firestop spacer securely VENT INSTALLATION 2 FT MIN LISTED VENT TOP STORM COLLAR ROOF FLASHING OVAL TO ROUND ADAPTER CEILING PLATE SPACERS 12 FT MIN LISTED BW VENT PIPE BASE PLATE HEADER PLATE 2 X 4 WALL STUDS CEILING PLATE SPACER LANCES Page 8 FIGURE 2 VE...

Страница 9: ...asconnectionusingconnectorthe samesizeasgasconnectionoffurnace CHECK ALL CONNECTIONS FOR GAS LEAKS WITH LEAK DETECTOR SOLUTION DO NOT USE OPEN FLAME STEP 9 For wall thermostat units see Wiring section for thermostat connections Make sure all connections are correct and connector stems arenottouching STEP 10 To fasten front panel to furnace be sure exposedportionofheaderisfreeofdebris Place outer p...

Страница 10: ...ght televisions fireplaces hidden hot or cold water pipes drafts etc The thermostatmustneverbeinstalledinanadjoiningroomwhere a door can be closed between the thermostat and wall furnace Thiswallfurnaceisequippedwithaselfgenerating control system Never connect to a 24 volt transformer or to the household electrical system Do not use more thermostatwirethanisincludedwiththewallfurnace Do not run th...

Страница 11: ... Read the information on the safety label 2 Set thermostat to it s lowest setting 3 Open cabinet door 4 Depress and turn gas control knob clockwise to OFF 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the information on the safety label If you don t smell gas go to the next step 6 Locate the pilot Follow metal pilot tube fr...

Страница 12: ...lating air passageways and venting systems of the appliance be kept clean 2 If the appliance has been equipped with the optional WFF81 C fan kit assembly the bearings of the motor should be oiled every six months with approximately 2 drops of S A E 20 oil 3 The appliance area must be kept clear and free of any combustible materials gasoline and other flammable vapors and liquids 4 It is essential ...

Страница 13: ...P N 40230 heat shield and the drilled holes in the front panel Attach using two 2 8x screws provided Make sure heat shield is between the BBSK control switch and the heat exchanger STEP7 Connect each end of the black wires to the two outside terminals on the BBSK control switch route wires down the inside of the front panel See Figure 11 STEP8 Straighten the bulb capillary tube using extreme care ...

Страница 14: ...9 BBSK CONTROL SWITCH 40225 SWITCH BRACKET 40230 HEAT SHIELD SENSING BULB FRONT PANELSIDE 6X1 4 2 SCREW CONTROL KNOB 8X1 2 2 SCREW CONTROLROD CAPILLARY TUBE FIGURE10 GASVALVE SENSINGBULB NYLONCLIP 10 24X3 8SCREW FIGURE12 GASVALVE BBSKCONTROL SWITCH BLACKWIRE FIGURE11 BlueWire BlueWire Blocked Flue Switch ...

Страница 15: ...STOP Read the information on the safety label 2 Turn temperature control knob clockwise to LO 3 Open cabinet door 4 Depress and turn gas control knob clockwise to OFF 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the information on the safety label If you don t smell gas go to the next step 6 Locate the pilot Follow metal p...

Страница 16: ...ewall Markasmallverticallinewhichalignswiththeslot located toward the rear of the fan kit casing STEP3 Using the four one inch screws provided secure the wall mounting bracket to wall 1 8 below the horizontal line Fan attachment bracket must be up and threaded nut sert aligned with the small vertical line Note Anchors not provided may be required STEP4 Removejunctionboxandconnect115vpowersupplyina...

Страница 17: ...ACK BLACK MOTOR WHITE GREEN GROUND WIRE L2 White L1 Black 115 VAC 60 HZ Less than 12 Amps If any of the original wire as supplied with this appliance must be replaced it must be replaced with type thermoplastic 105 degree C wire or its equivalent WFF81 C WIRING SCHEMATIC Page 17 ...

Страница 18: ...ce is installed attach rear register grilleas shown in Figures 16 17 by insertion over plaster ground and attach with sheet metal screws provided STEP 5 Damper as showninFigure17canbeadjustedfromfullopenformaximumheattofullyclosed Page 18 14 3 8 12 5 8 8 1 4 PLASTER PLASTER STUD PLASTER STUD PLATE 45 3 4 ROUGH INDIMENSIONSFORREARREGISTER FIGURE13 OPENING7 8 FROMEACH STUD HOLEFOR BACK REGISTER PLAS...

Страница 19: ...CES Page 19 INNERPANEL FIGURE 15 Plaster Ground Frame Closed Position Rear Register Grille 2 x4 Upright Finished Wall Casing Open Position Damper FIGURE 17 Finished Wall Heater Casing Casing Opening Retainer Screw Holes Rear Register Grille Plaster Ground Frame FIGURE 16 Form 84504 REV 07 98 ...

Страница 20: ...ean burner ports Do not enlarge ports 3 Low gas pressure 3 Check gas supply pressure 4 Pilot decreases in size when main burners 4 Supply piping is inadequately sized Consult local come on gas utility or competent installer 5 Air shutter open too far 5 Close air shutter to proper setting as outlined in these instructions slight yellow tipping is allowable on L P Gas See Page 12 6 Drafts around app...

Страница 21: ... A Vent too short A The vent should terminate a minimum of 12 feet above the floor See Figure 2 Also the top of the vent must be at least 2 foot above any obstacle within a 10 foot radius including the roof See Figure A B Restriction in B All type B vents shall extend in a generally vertical direction with offsets not exceeding 45 vent system degrees except that a vent system having not more than ...

Страница 22: ...O B factory GRAVITY WALL FURNACE LIST PRICES MARCH 2013 57 59 60 55 58 56 FSK A FREESTANDING KIT 19 14 18 15 16 17 21 20 13 48 49 WFF81 C FAN KITUsed on Single and Dual Wall models REARREGISTERKIT Used on Single Wall models only 27 25 26 23 22 24 THERMOSTAT 40 BURNERASSEMBLY SINGLE WALL FURNACE 38 39 35 29 36 31 30 32 44 BURNERASSEMBLY DUAL WALL FURNACE 44 29 38 29A 36 43 39 35 32 33 28 Page 22 3 ...

Страница 23: ... N A 40220 2 60 Bell Pull 26 85003 1 60 for W506F Register Assembly 27 40355 23 80 Orifice Coupling 30 84631 5 80 N A N A Installation Manual N A 84504 N C Elbow 3 8 90 Degree 31 84124 2 50 N A N A Orifices 32 Manifold 33 N A N A 84072 33 30 Floor Plate Assembly 55 40405 24 60 Pipe Nipple N A 84123 2 20 N A N A Right Side Assembly 56 40410 37 60 Pilot Tubing w Fittings 44 74452 8 60 74452 8 60 Upp...

Страница 24: ... locate the installer the user should write directly to the manufacturer and the name of an alternative service source will be supplied The product safety registration card packed inside the appliance must be completed and returned to the factory THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED WHETHER WRITTEN OR ORAL ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNE...

Отзывы: