![Coyote C1DBLP Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/coyote/c1dblp/c1dblp_use-and-care-manual_2674375021.webp)
19
Note: You will need to remove your cooking grates to see
the electrodes.
•
Check your igniter battery and replace if needed.
•
Check for loose wire connections to the igniter or electrodes.
•
Check to see if debris is blocking the electrodes.
•
If the igniter is not working, can you light the burner with a
lighter?
Flare-ups
•
Ensure burner is not placed directly in the path of wind.
Be sure drip pan is clean (do not use aluminum foil on drip pan.)
Note: Some flare-ups may be inevitable if cooking greasy
foods.
Yellow Flames
•
Check the burner inlet for obstructions, particularly at air inlets
for each burner.
•
Side burner should not be in an area that is too windy.
Flame blows out on low setting
or has uneven heat distribution.
•
Check for spider webs or insect nest in venturi and clean
venturi.
•
Cold side burner needs to be preheated for 5 minutes on high
setting.
•
Venturi may be misaligned and needs to be lined up over
orifices.
•
Cold and windy weather will require you to move side burner
away from the wind.
•
Lack of fuel. Check to see cylinder valve is open and cylinder
has fuel.
Low heat with the knob on
“HIGH”
•
Check to see if the fuel hose is bent or kinked
•
Make sure the cooking area is clear of dust
•
Check your gas supply and gas pressure.
•
If it is only one burner that appears low, make sure the orifice or
burner is clean.
Burner is Too Hot
•
Excess grease build-up causing grease fires.
•
Damaged or faulty regulator.
Replace with factory authorized parts.
•
Cook on a lower temperature setting.
Flame behind control panel or
control knob area.
IMMEDIATELY shut off cylinder valve and allow side burner to
cool.
•
C
heck for spider webs or insect nest in venturi and clean
venturi.
•
Gas is leaking from a faulty connection. Tighten connections
with an adjustable wrench and replace damaged parts. Perform
a leak test on all connections before cooking on side burner
again.
•
Venturi may be misaligned and needs to be lined up over
orifice.
Fire at any connection.
IMMEDIATELY shut off cylinder valve and allow side burner to
cool.
•
Gas is leaking from a faulty connection. Tighten connections
with an adjustable wrench and replace damaged parts.
•
Perform a leak test on all connections before cooking on the
side burner again.