background image

Migration Process

The following describes the process of converting an EQ/OS 8.6 configuration to EQ/OS 10. It is
recommended that the migration be executed on a "clean" Equalizer, meaning, without configured
objects. If there are configured objects on your system, it is advisable to review the names and IP
configuration to verify that there are no conflicts with the migrating EQ/OS 8.6 configuration. If
there are conflicts, they will be noted and displayed when the migration script is executed.

General Work flow

1. On EQ/OS 8.6, create a backup archive of the system. You will not be able to downgrade to

EQ/OS 8.6 in the event that a downgrade becomes necessary in the future.

2. Upgrade your EQ/OS 8.6 system to EQ/OS 10.

3. Upload the backup file to EQ/OS 10.

4. Convert the backup file to a EQ/OS 10 configuration script.

5. Run the script.

In Version 8.6, outbound NAT may be configured to use the server IP, cluster IP, failover IP
or the subnet IP (default case). However, the converter will look for a subnet to which the
server belongs and configure it to NAT out of that subnet IP . If no such subnet exists, then
outbound NAT for that Version 8.6 server must be manually converted to EQ/OS 10.

For the converter to configure/convert outbound NAT from Version 8.6 to EA/OS 10, the
Version 8.6 global flag - enable_outbound_nat must be set.

Static Routes:
A static route configured in Version 8.6 is converted if the gateway IP is a part of an existing
subnet. If no such subnet exists, the Version 8.6 static route must be manually converted to
EQ/OS 10.

Copyright © 2015 Coyote Point Systems, A Subsidiary of Fortinet, Inc.
All Rights Reserved.

5

Equalizer Administration Guide

Содержание EQ/OS 10

Страница 1: ...Application Delivery Controller 2 04 Version 8 6 to 10 Configuration Converter April 24 2015 The recognized leader in proven and affordable load balancing and application delivery solutions ...

Страница 2: ...Q OS 10 0 Configuration Converter Sections include EQ OS 8 6 to EQ OS 10 Configuration Converter 2 Copyright 2015 Coyote Point Systems A Subsidiary of Fortinet Inc All Rights Reserved 1 Equalizer Administration Guide ...

Страница 3: ... are global objects in EQ OS 10 that must be placed in server pools before they are associated with clusters Configuration Conversion Notes 1 You must be running EQ OS 8 6 0i patch1 to upgrade to EQ OS 10 2 SSL Certificates are not converted They will need to be to manually reinstalled after the migration to EQ OS 10 is complete 3 In EQ OS 8 6 outbound NAT could be configured to use the Server IP ...

Страница 4: ...converting the configuration Clusters Converted completely with the exception of Certificates as described below Send and receive socket options are not converted because they are deprecated These are automatically managed in EQ OS 10 Cluster VID is now deprecated See the note about Server VID above VMware server configuration for VLB basic Converted completely Email alerts Converted completely Th...

Страница 5: ...n migrating to EQ OS 10 a Server Pool will be created using the cluster server details described A server instance si will be created for the new EQ OS 10 server and assigned to a new cluster For example A server pool srvpl is created with a new server instance si srvpl cl00 si cl00_sv00 A new cluster is created with the new server pool attached cluster cl00 srvpl cl00 However if there are duplica...

Страница 6: ... the backup file to EQ OS 10 4 Convert the backup file to a EQ OS 10 configuration script 5 Run the script In Version 8 6 outbound NAT may be configured to use the server IP cluster IP failover IP or the subnet IP default case However the converter will look for a subnet to which the server belongs and configure it to NAT out of that subnet IP If no such subnet exists then outbound NAT for that Ve...

Страница 7: ... script file also in the EQ OS 10 data store It will also create files for any sorry responders in the datastore The script will be a list of eqcli commands to create converted configuration objects and comments describing parameters which could not be converted For example cluster myclust proto tcp ip 10 0 0 10 port 1 range 4999 stickyto 3500 idleto 36000 Unsupported user touch option desc touch ...

Страница 8: ...cates first 7 If the script completed with an error you can modify the offending command and restart the script from that line eqcli files edit filename eqcli run_script filename start line For example eqcli files edit myscript eqcli run_script myscript 5 Note The default editor that is used when the files edit command is executed is ee If you are editing a long file it may be helpful to jump to p...

Страница 9: ...tion of your backup file After selecting a file from either method described in steps 5 and 6 proceed with step 7 Note By default VLANs and Subnets in the EQ OS 8 6 configuration will be converted Enabling the Ignore VLANs and Subnets option will cause the converter to ignore VLANs and Subnets in the EQ OS 8 6 configuration 5 To upload from a URL or FTP Server a Click on the FTP URL option and ent...

Страница 10: ...elect it and click on Open to begin the upload process 7 The Verify and Run Configuration Script screen is a line numbered text editor Here you can modify a script as needed before continuing with the conversion Copyright 2015 Coyote Point Systems A Subsidiary of Fortinet Inc All Rights Reserved 9 Equalizer Administration Guide ...

Страница 11: ...ersion script in the file store Refer to the Equalizer Administration Guide for instructions on accessing and editing files in the data store using the CLI Click on Discard to discard the script b Click on Continue to execute the script on Equalizer starting at the line on which the error occurred If no errors occur and the script runs to completion a Configuration Complete message will be display...

Отзывы: