Water Filtration System Performance Data Sheet

Model:  P-08L  

This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53 and 58 for 

the reduction of the substances listed below. The concentration of the indicated substances in water entering the 

system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as 

specified in NSF/ANSI 42, 53, 58 and 372.

Substance

Influent Challenge Concentration 

(mg/L unless specified)

Maximum Allowable Product Water 

Concentration

(mg/L unless specified)

Percent Reduction 

(%)

Arsenic (Pentavalent)

0.050 ± 10%

0.010

97.8

Barium

10.0 ± 10%

2.0

97.2

Radium 226/228

25 pCi/L

5 pCi/L

80

Cadmium

0.03 ± 10%

0.005

98.2

Chromium (Hexavalent)

0.3 ± 10%

0.1

98.6

Chromium (Trivalent)

0.3 ± 10%

0.1

99.4

Lead

0.15 ± 10%

0.010

99.1

Copper

3.0 ± 10%

1.3

98.1

Selenium

0.10 ± 10%

0.05

98.3

TDS

750 ± 40

187

89.9

Aesthetic Chlorine

2.0 ± 10%

≥ 50% reduction

79.3

VOC*

0.300 ± 10%

≥ 95% reduction

99.6

While testing was performed under laboratory conditions, actual performance may vary.

General Operating Information:

Rated Capacity

680.0 L (for VOC)

11000.0 L (for Aesthetic Chlorine)

Min-Max operating pressure:

138 kPa ~ 827 kPa

Min-Max feed water temperature:

5 ºC ~ 35 ºC

Rated Service Flow

0.26 L/min

Daily Water Production Rate

152.6 L/d

Product Efficiency Rating

43.3 %

•  Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

before or after the system.

•  Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user 

responsibility, and parts and service availability.

•  The influent water to the system shall include the following characteristics:

o  No organic solvents
o  Chlorine: < 2 mg/L
o  pH: 7 - 8
o  Temperature: 5 ºC ~ 35 ºC
o  Iron: < 2 mg/L
o  Turbidity: < 1 NTU
o  Hardness: < 1 000 mg/L

Содержание P-08L

Страница 1: ...Water Filtration Device P 08L For your safety and proper use of the product please read this User s Manual before use Warranty card is included in this User s Manual English MY...

Страница 2: ...contamination Preventssecondary contamination FEATURES Continuous dispensing function Turn the water dispensing lever 45 clockwise and lock it in place to conveniently dispense purified room temperatu...

Страница 3: ...DEAR CUSTOMERS Please keep the User s Manual where it can be readily reached or found CONTENTS 03 SAFETY INFORMATION Danger Warning Caution 05 PARTS NAME 06 WATER FILTRATION PROCESS 07 INSTALLATION PR...

Страница 4: ...l objects or flammable materials on top of this product Warning If not observed serious injury or property damage could occur Do not use or store combustible gases or flammable materials near this pro...

Страница 5: ...er Completely close the Storage tank cover inside the product before use If you have not used this product for a long time completely drain all water from the Storage tank then empty of newly purified...

Страница 6: ...L For your safety and proper use of the product please read this User s Manual before use Warranty card is included in this User s Manual Outlet hose blue Top cover Inlet hose orange Water dispensing...

Страница 7: ...as the function to remove chlorine volatile organic compounds VOC s STEP 3 RO MEMBRANE FILTER RO membrane filter has the function to remove water contaminants such as heavy metals waterborne microorga...

Страница 8: ...connection The summary for the proper installation of the water filtration device 1 Close main water supply valve to separate the faucet 2 Apply the Teflon tape to the adaptor and fit it to the pipe...

Страница 9: ...in place Gently turn the water dispensing lever counter clockwise to orient it upward to lock room temperature water HOW TO USE To Drink Room Temperature Water Large Volume Dispensing To Lock Room Tem...

Страница 10: ...INSTALLATION Follow the instruction for installation Connect the inlet hose orange to the tap Connect the outlet hose blue Outlet hose blue connection Inlet hose orange connection Connection valve...

Страница 11: ...ll II Install in a place where the floor is level and strong Cold water pipe Be sure to connect to the cold water pipe If you connect to the hot water pipe the device filters may be damaged Be cautiou...

Страница 12: ...ection valve 2 Use continuous dispensing to completely drain all water from inside the device see p 8 3 Lift the latch at the back of the device to open the top cover Open the clips in 5 places affixi...

Страница 13: ...erial filter from the Storage tank cover and shake in purified water to clean then reinstall 5 Wipe the Storage tank surfaces with a soft cloth 6 Rinse the Storage tank clean with water from the devic...

Страница 14: ...close the Storage tank cover Otherwise insects or dirt may enter Do not use chemicals or detergent when cleaning the Storage tank If chemicals or detergent are not completely washed away they may be...

Страница 15: ...f water from the device will decrease Predicted filter replacement cycles may vary depending on source water quality and amount of water used P 08L Filter name Recommended replacement cycle Neo Sense...

Страница 16: ...1 Lock the connection valve and completely drain all water from inside the device see p 8 2 Open the product side cover FILTER REPLACEMENT Replace the filters 2 1...

Страница 17: ...re to first drain purified water Tips Contact a customer service center to replace fittings tubing and faucets after 5 years of use free of charge Tips Use new filters only after washing them Neo Sens...

Страница 18: ...nd clean the Storage tank Is it time to replace a filter Request a filter replacement Water doesn t come out Is the water cut off or is the connection valve locked Open the connection valve The faucet...

Страница 19: ...0 mm depth x 434 mm height Net weight 4 9 kg Effective water capacity 5 400 L Daily water capacity 132 L d NSF ANSI 58 standard 345 kPa 25 C NaCl 750 ppm Operating pressure tap water 138 kPa 827 kPa O...

Страница 20: ...om temperature watertank Decompression valve Room temperature waterdispensing Drainwater adjustmentvalve Antibacterial filter Drain water NEO SENSE FILTER RO MEMBRANE FILTER PLUS INNO SENSE FILTER P 0...

Страница 21: ...20 19 WATER FLOW DIAGRAM Others MEMO...

Страница 22: ...10 99 1 Copper 3 0 10 1 3 98 1 Selenium 0 10 10 0 05 98 3 TDS 750 40 187 89 9 Aesthetic Chlorine 2 0 10 50 reduction 79 3 VOC 0 300 10 95 reduction 99 6 While testing was performed under laboratory co...

Страница 23: ...in some well water Arsenic in water has no color taste or odor It must be measured by a lab test Public water utilities must have their water tested for arsenic You can get the results from your wate...

Страница 24: ...lbenzene 0 088 0 001 99 ethylene dilbromide EDB 0 044 0 00002 99 haloacetonitriles HAN bromochloroacetonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetoritrile 0 022 0 024 0 0096 0 015 0...

Страница 25: ...24 23 MEMO PERFORMANCE DATA SHEET P 08L Others...

Страница 26: ...obligations other than those specifically identified in the preceding section COWAY is not responsible or liable for personal injury or property damage of any kind even if arising from a breach of thi...

Страница 27: ...he part of the OWNER Waiver COWAY s failure at any time to enforce or rely upon any of the terms or conditions stated herein shall not be construed to be a waiver of its rights hereunder Obtaining War...

Страница 28: ...www coway com 1227058 002...

Отзывы: