Cove DW2450 Скачать руководство пользователя страница 5

MODES

Modes are the dishwasher's operational states, in which the dishwasher varies its behavior according to instructions from the following:

User input from the UIM

Connected appliance communications from a tablet or other connected device

Smart Grid

Mode

Description

Power-Up mode

The unit is 

first

 turned on.

User mode

The unit is used for day-to-day, ordinary operation.

Standby Power mode

The unit enters a low-power state after a 

specified

 period of

inactivity.

Sabbath mode

The unit is set up by the user for certain religious observances.

Child Lock mode

The unit's UIM is locked to prevent unwanted operation.

Showroom mode

The unit is set up by sales staff for demonstration purposes.

Service Diagnostic mode

Activated by Service personnel in the user's residence. See 

Service Mode

 on page 47.

Power-Up Mode

Power-Up mode is the control system's initial power-up/boot sequence, when the unit 

first

 connects to AC power. In Power-Up mode, all

power supplies and all electronics initialize their associated circuitry and components.

Power-Up mode does not have water softener regeneration messaging, Bluetooth PIN messaging, diverter valve movement, or lighting.

Digital Wi-Fi connection X13’s ON/OFF state is OFF until after the boot sequence, when the software will set it to either OFF or ON.

If the unit does not successfully pass though Power-Up mode, the UIM shows "PF - Call Service."

User Mode

User mode is the normal, day-to-day operation mode of the dishwasher. This mode does not require any key press combinations to enter
or exit, but the unit's control system may enter and exit User mode automatically, for example entering Standby Power mode after a
period of inactivity.

User mode allows all control system functions including Smart Grid requests, Bluetooth pairing, water softener regeneration messaging,
diverter valve movement, pressure-based drain pump control, and the digital Wi-Fi connection X13.

Standby Power Mode

During periods of inactivity, the unit can automatically enter a Standby Power mode in which it consumes no more than 0.5 W of power.

Standby Power mode occurs when the unit has either:

Had no door movement and no communication and has not logged any errors for 15 minutes.

Completed its wash cycle with the door still latched shut.

In Standby Power mode, the UIM is blank, and all control system outputs are disabled including tub lighting, water softener regeneration
messaging, and diverter valve movement. Pressure-based drain pump control is allowed. If the pressure goes above its range, the unit
will exit Standby Power mode to communicate the error.

Standby Power mode is exited by moving the door, pressing any UIM key, receiving a Bluetooth pairing PIN display command, or
triggering an error.

Standby Power mode never occurs when the unit's Connect? option is turned on.

DW2450 and DW2450WS Service Manual

Controls and Operation

 

service.subzero.com

828019 REV. A     02/2019

5

 

Содержание DW2450

Страница 1: ...xpress written consent of Cove Appliance Inc Cove Appliance Inc all rights reserved COVE PRODUCT RATING PLATE INFORMATION The product rating information is located inside the dishwasher tub on the left hand side Important information for each product is listed on the product rating plate Rating plates identify Model name and part number Electrical and power specifications Serial number MODEL DESCR...

Страница 2: ...nates to indicate the status of the cycle LIGHT STATUS Blue A delayed start has been selected Touch Start each time the door is opened prior to the start time Red The cycle has started Green The cycle is complete No Light The door was not closed within four seconds after touching Start the cycle has been complete for more than two hours or the door has been opened Water Softener For water softener...

Страница 3: ... duration and intensity Auto starts with a prewash cycle during which the unit drains and fills to 1 1 gal The unit then washes and takes turbidity readings once per minute calculating the average turbidity and the change in the average turbidity as time passes The unit washes and accumulates turbidity data for 10 minutes up to 15 minutes if the turbidity is not stable Then it selects a cycle base...

Страница 4: ...extends the cycle time by 10 minutes Sani Rinse Increases the rinse water temperature and extends the rinse time Extended Dry Extends the dry time by 30 minutes Extra Dry Increases the rinse water temperature and extends the dry time by 30 minutes Top Racks Only Directs wash functions to upper and middle racks only Sanitizes per NSFIANSI standard 184 for residential dishwashers Interrupt a Cycle T...

Страница 5: ...Up mode the UIM shows PF Call Service User Mode User mode is the normal day to day operation mode of the dishwasher This mode does not require any key press combinations to enter or exit but the unit s control system may enter and exit User mode automatically for example entering Standby Power mode after a period of inactivity User mode allows all control system functions including Smart Grid requ...