background image

1

1 (YE)

TX+

M8

2

3 (WH)

RX+

3

6 (BU)

RX-

4

2 (OG)

TX-

Shield

RJ45

Ethernet ports

(embedded switch)

1 (BR)

24 V DC

M8

2 (WH)

NC*

3 (BU)

GND

4 (BK)

NC*

*NC: Not Connected

24 V DC

power supply

+

M8 COVAL bus

termination

Power supply Rear connector

1 (BR)

1

24 V DC

M8

2 (WH)

2

CAN_H

3 (BU)

3

GND

4 (BK)

4

CAN_L

M8

COVAL bus connectors

Fieldbus connectors

COVAL bus

(com + 24 V DC)

I

Consommation de courant d’un îlot LEMCOM / 

Current consumption of a LEMCOM island

Stromverbrauch einer LEMCOM-Inselanlage / 

Consumo di corrente di un’isola LEMCOM / 

Consumo de corriente de un grupo LEMCOM

Nombre de modules / 

Number of modules

 / Anzahl Module

Quantità moduli

 / Número de módulos

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Consommation maximale de courant (mA) alimentation 24 V / 

Maximum 

current draw (mA) 24 V supply

 / Max. Stromaufnahme (mA), bei 24 V / 

Consumo massimo di corrente (mA) alimentazione 24 V

 / Consumo 

eléctrico máximo (mA) alimentación 24 V

150

250

350

450

550

650

750

850

950

1050 1150 1250 1350 1450 1550 1650

B

Quick Start Guide

v04 - 03/2020

A

ZA des Petits Champs 26120 Montélier France

Tel : +33 (0)4 75 59 91 91 - www.coval.com

LEMCOM

 modules

QSG EIP LEMCOM EN (v04-2020)      - 1 -

I - ELECTRICAL CONNECTIONS
A- Wiring instructions

Factory fieldbus (EtherNet/IP™) is connected to one of the 2 ports of the embedded Ethernet 
switch (shielded M8/RJ45 cable).

Connect the “COVAL bus” using the provided bridge connectors or M8/M8 female cable for re-
mote modules.

24V DC power supply is connected to the rear connector of the last secondary module of the 
island (or to the rear connector of master module if used as standalone LEMCOM) through the 

COVAL bus termination cable.

Standalone secondary module or “Secondary only” island?

Refer to chapter VI for wiring and initial setup.

The LEMCOM vacuum pump must be used with power supply units that provide 
a Protective Extra Low Voltage (PELV) and with an isolation of the supply voltage 

according to EN60204.

This guide provides first-time users with information on wiring the different modules of a 
LEMCOM island and on setting up the LEMCOM.

EN

B- Consumption

The LEMCOM structure implies that all vacuum generators connected together on the COVAL 
bus are electrically supplied by the same power source. The consumption table(left) must be fol-
lowed when calculating the required power supply voltage and amperage.

Содержание LEMCOM

Страница 1: ...33 0 4 75 59 91 91 www coval com LEMCOMmodules QSG EIP LEMCOM EN v04 2020 1 I ELECTRICAL CONNECTIONS A Wiring instructions Factory fieldbus EtherNet IP is connected to one of the 2 ports of the embedd...

Страница 2: ...h 5 m CDM8RJ45L10 length 10 m Cat 5 shielded Ethernet cable M8 straight female 4 pin on both ends suitable for drag chain use 80003053 length 1 m COVAL bus bridge connector 80001231 120 COVAL bus term...

Страница 3: ...82 10 2 1 Control panel Network and internet Network Connections Ethernet Properties 2 2 IP address 10 3 182 10 The computer and the LEMCOM module must be on the same network The IP address of the LEM...

Страница 4: ...back in 5 4 Release the button when MS LED starts flashing green IP address is now 10 3 182 163 INCORRECT SETTINGS INDICATION If the recommendations provided above are not observed when configuring a...

Страница 5: ...N Object gripped signal vacuum level L1 threshold otherwise OFF B1 Custom led LED configurable according to customer requirements refer to main user manual section 4 1 for detailed meaning MS Module S...

Страница 6: ...ager software or web server can be used to complete this operation 1 Wire the modules Connect secondary module s to the master LEMCOM module using M8 M8 female cables 2 Connect to the master module us...

Страница 7: ...r to the main user manual ref LMEIP UK x 1155UM0067 for detailed set up instructions data mapping and general recommendations 1 LEMCOM general properties With respect to the EtherNet IP network the LE...

Страница 8: ...vices available in the device 1 Install Electronic Data Sheet create a New Module Download the EDS from the COVAL website https doc coval com lemcom 1 1 In RSLogix5000 go to Tools EDS Hardware Install...

Страница 9: ...more B Manual setup using Generic Ethernet Module Connection settings can be manually defined in RSLogix5000 or any other controller robot soft ware using a Generic Ethernet Device 1 1 Add a new Gener...

Страница 10: ...to subscribe to our LEMCOM Technical Newsletter to stay informed about new features firmware updates tutorials etc https www coval international com products mini vacuum pumps with fieldbus communica...