Quick Start Guide
QSG EIP LEMCOM EN (v04-2020) - 5 -
V- FRONT PANEL INDICATOR
Colors: Ox (Orange) - Gx (Green) - Bx (Blue) - MS, NS (Red/Green).
Ref.
Related to Meaning
O1
Parts
handling ON: Blow-off command enabled / otherwise OFF
G1
Parts
handling ON: vacuum is generated / otherwise OFF
Gv
Parts
handling
Gv provides an indication of the vacuum valve status:
If Normally Closed (NC) valve
Gv behaves as G1
If Normally Open (NO) valve
Gv OFF: vacuum is generated / otherwise
ON
G2
Parts
handling ON: Object gripped signal (vacuum level > L1 threshold) / otherwise OFF
B1
Custom
led
LED configurable according to customer requirements (refer to main user
manual / section 4.1 for detailed meaning)
MS
Module
Status
Indicates the current status of the device (refer to main user manual /
section 4.2 for detailed meaning)
NS
Network
Status
Indicates the current status of the EtherNet/IP or COVAL bus network
interface (refer to main user manual / section 4.3 for detailed meaning).
O2/O3
Ethernet
network
Ethernet link / activity - Left Port (02), Right Port (03)
OFF : No network connection
Steady ON: Network connection OK but no activity
Blinking: Network connection is OK and activity
SET
Setting
button
Master module: IP address reset
Secondary module: COVAL bus address assignment and reset