LEMCOM CANopen®
– User manual
Wiring
instructions
COVAL
– LMCOP-EN-A-1155UM0068
10/49
3
WIRING INSTRUCTIONS
- Connector type: M8 male
Figure 2
– Wiring a LEMC--X---W2GB4 island
3.1
CAN ports
A CAN interface is integrated in the LEMCOM (model W2) and features two CAN ports on the front
of the module.
Figure 3
– Wiring instructions (M8 – CAN bus ports)
M8
1 (BR)
2 (WH)
3 (BU)
4 (BK)
NC
CAN_H
CAN_GND
CAN_L
NC = Not Connected
BR: brown / WH: white / BU: blue / BK: black
CAN ports
24 V DC
Power supply
+
M8 COVAl bus
terminator
COVAL bus
(com + 24 V DC)