The rate of flow in the discharge pipe must keep any 
solids present in suspension in the fluid. To meet 
minimum flow requirements (2 feet (.6 m) per second in 
discharge line), size pipe as follows:

Pipe Size (In/cm)

Flow Rate (GPM/LPM)

1-1/2 (3.8)

12 / 45

2 (5.1)

21 / 79

2-1/2 (6.3)

30 / 113

3 (7.6)

48 / 181

The pump must always be lifted by the lift-out chain or 
cable and never by the power supply cable. See Cord 
Lift Warning.
4.  To reduce motor noise and vibrations, a short length 

of rubber hose, e.g. radiator hose, can be connected 
into discharge line near pump using suitable clamps. 

5.  If the pump discharge line is exposed to outside 

subfreezing atmosphere, then the portion of line 
exposed must be installed so any water remaining in 
pipe will drain to outfall by gravity. Failure to do this 
can cause water trapped in discharge to freeze which 
could result in damage to pump.

6.  Install a 2” check valve in the horizontal portion of 

the discharge pipe. Make certain, the flow indicating 
arrow, points away from the pump. This check valve 
will keep the water from either running back into the 
basin or into the area being pumped out when the 
pump is not running. Check valve should be a free 
flow valve that will easily pass solids.

 

NOTICE For best performance of check valve when 
handling solids, do not install it with discharge 
angled more than 45° above the horizontal. Do not 
install check valve in a vertical position as solids 
may settle in valve and prevent opening on startup.

7.  Drill a 3/16” (4.7mm) hole in discharge pipe 

about 1”-2” (2.5 - 5.1cm) above pump discharge 
connection (but below check valve) to prevent the 
pimp from airlocking.

8.  Insert the float switch piggy-back plug into a properly 

grounded outlet and the pump plug into the piggy-
back plug.

9.  Check the installation by observing the pump 

operation through one complete cycle. Make sure 
that no parts of the assembly interfere with the 
float switch.

 Risk of flooding. Can cause personal injury 

and/or property damage. Failure to make this operational 
check may lead to improper operation, premature failure, 
and flooding.

Electrical

 Risk of electric shock. Can shock, burn or 

kill. When installing, operating, or servicing this pump, 
follow safety instructions listed below.
1.  DO NOT splice the electrical power cord.
2.  DO NOT allow electrical cord plug to be submerged.
3.  DO NOT use extension cords. They are a fire hazard 

and can reduce voltage sufficiently to prevent 
pumping and/or damage motor.

4.  DO NOT handle or service pump while it is 

connected to power supply.

5.  DO NOT remove grounding prong from plug or 

modify plug.To protect against electrical shock, the 
power cord is a three-wire conductor and includes 
a 3-prong grounded plug. Plug pump into a 3-wire, 
grounded, grounding-type receptacle. Connect pump 
according to electrical codes that apply.

For automatic operation, plug or wire pump into an 
automatic float switch or pump controller. Pump will run 
continuously when plugged directly into an electrical 
outlet. Connect pump to its own individual branch 
circuit with no other outlets or equipment in the circuit. 
Size fuses or circuit breakers according to Specifications 
chart.

 Risk of electric shock. Can shock, burn or 

kill. Be sure that power supply information (Voltage/
Hertz/Phase) on pump motor nameplate matches 
incoming power supply exactly. Install pump according 
to all electrical codes that apply.

Operation

NOTICE Do not allow pump to run in a dry sump. It will 
void the warranty and may damage the pump.
An automatic overload protector in the motor will protect 
motor from burning out due to overheating/ overloading. 
When motor cools down, overload protector will 
automatically reset and start motor.
If overload trips frequently, check for cause. It could be 
a stuck impeller, wrong/low voltage, or electrical failure 
in motor. If an electrical failure in the motor is suspected, 
have it serviced by a competent repairman.
Pump is permanently lubricated. No oiling or greasing 
is required.

Содержание CLW750

Страница 1: ...ion Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 6 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instala...

Страница 2: ...k Check your local codes before installing You must comply with their rules Only qualified personnel should install the pump and associated control equipment Ground the pump according to all applicabl...

Страница 3: ...products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen se...

Страница 4: ...ipe union in the discharge piping to allow removal for servicing Use PTFE tape on pipe threads Do not use ordinary pipe joint compound on plastic pipe or pump Pipe joint compound can attack plastics a...

Страница 5: ...mbly interfere with the float switch Risk of flooding Can cause personal injury and or property damage Failure to make this operational check may lead to improper operation premature failure and flood...

Страница 6: ...unexpected starts Can result in electrical shock or pinching of hands or tools If power to pump is on when thermal overload resets pump may start without warning Disconnect power before servicing pump...

Страница 7: ...n un choque el ctrico fatal Verifique sus c digos de normas locales antes de realizar la instalaci n Usted debe cumplir con sus reglas S lo un personal calificado deber instalar la bomba y el equipo d...

Страница 8: ...aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine L...

Страница 9: ...ber a debe ser de 1 1 2 como m nimo para acarrear el volumen de descarga de la bomba Verifique los c digos locales para determinar si es necesario instalar una v lvula de retenci n en su sistema En cl...

Страница 10: ...les Si se ignora esta recomendaci n de verificar el funcionamiento existe el riesgo de un funcionamiento incorrecto fallas prematuras e inundaci n Instalaci n el ctrica Riesgo de choque el ctrico Pued...

Страница 11: ...lotador para asegurarse de que haya el m ximo de juego posible La bomba no se apaga 1 Verifique el funcionamiento la ubicaci n y el juego adecuado de los flotadores autom ticos del interrup tor o del...

Страница 12: ......

Отзывы: