background image

Operation • Maintenance 

5

All suction connections must be airtight. Make sure 
suction lift is not more than 25’ (7.6M). Fill pump body 
through priming port before starting pump. Start pump; it 
should pump water in under 10 minutes (depending on 
length of suction hose and height of pump above water).

Maintenance

Motor is lubricated at factory for life of bearings. Pump 
seal is water cooled and self lubricating.
Motor has auto-reset thermal overload. If motor 
overheats, overload will cut off power to prevent 
damage and will reset after motor cools. If overload trips 
repeatedly, check pump for cause (low voltage, clogged 
impeller, etc.).

 Risk of electric shock. Can shock, burn or 

kill. Disconnect motor from electrical power before 
servicing pump.
Always replace both brushes - to avoid fire hazard, never 
replace just one.

Seal Changing Procedure

 Risk of electric shock. Can shock, burn or 

kill. Unplug pump before continuing.
1.  Unplug the pump from the outlet and remove all 

piping or hoses from the pump.

2.  To avoid breaking the brushes when you remove or 

replace the motor shaft, remove the motor brushes 
(see Brush Changing Procedure). Put the brushes 
where they will not get lost or damaged while 
you proceed.

3.  Remove 4 screws from the back of the pump body 

(Ref. 1, Repair Parts) and remove the pump body 
from the motor. Remove the old Square-cut O-Ring 
(Ref. 4C) from the assembly.

4.  Unscrew the impeller (Ref. 4A) from the motor shaft 

and discard it.

5.  Pull the seal plate (Ref. 5) from the motor shaft. 
6.  Turn the seal plate face down (See Figure 4A) and 

use a screwdriver or small tube to push the stationary 
seal half out of the seal plate (Figure 4B).

IN

OU

T

3/4" Discharge 

Hose or Plastic 

Pipe

NOTICE:

Pump suction port must

be 25' (7.6 m) or less 

above water level.

Max. water temp. is

120° F (48.9°C).

115 Volt grounded

outlet box. 

Priming 

Plug

Puddle Scoop 

(Clean Frequently)

Operate pump on

115 volt curent only!

3/4" Suction Hose 

5610 0407

Figure 3: Typical Installation. Be sure to connect the 

pump to a grounded outlet. Do not immerse the pump 
and motor!

A

B

C

5678 0807

Figure 4: Seal Changing Procedure

Содержание CLBU10C

Страница 1: ...For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 9 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimien...

Страница 2: ...y property damage or death Do not pump gasoline or any other flammable liquids with pump Do not use pump in atmosphere that might contain flammable fumes or vapors 6 Do not pump chemicals or corrosive...

Страница 3: ...n commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been...

Страница 4: ...igure 1 Plastic pipe can be used for all installations Electrical Risk of electric shock Can shock burn or kill Unplug pump before servicing it Do not handle pump or attempt to work on pump with wet h...

Страница 5: ...outlet and remove all piping or hoses from the pump 2 To avoid breaking the brushes when you remove or replace the motor shaft remove the motor brushes see Brush Changing Procedure Put the brushes wh...

Страница 6: ...wires on the motor side of the crimps as close to the connectors as possible in other words leave yourself as much wire in the motor as possible 4 Strip all the wires back about 5 8 from the wire ends...

Страница 7: ...0407 Step 1 IN IN OUT OUT 5604 0407 IN IN OUT OUT A B IN OUT IN OUT IN OUT IN OUT Step 2 IN IN OUT OUT 5604 0407 IN IN OUT OUT IN OUT IN OUT IN OUT IN OUT A B Step 6 5605 0407 IN OUT Step 3 5606 0407...

Страница 8: ...nd or pressure Air pockets or leaks in suction line Check suction piping Clogged impeller Remove and clean Pump loses prime Air leaks in suction line Check suction piping Excessive suction lift and op...

Страница 9: ...Shaft Seal 1 4C Square Cut O Ring 1 5 Seal Plate 1 6 Handle With Hardware 1 C54 30 7 Power Cord 1 PS17 1507 8 Brush Kit Includes 1 Pair of Brushes with springs and Retainer Caps 1 FPPKG 226 P2 9 Motor...

Страница 10: ...ar lesiones graves da os materiales o muerte No bombee gasolina ni ning n otro l quido inflamable No use la bomba en una atm sfera que pueda contener humos o vapores inflamables 6 No bombee productos...

Страница 11: ...ados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de Coun...

Страница 12: ...muerte Desenchufe la bomba antes de efectuar el servicio de la misma No toque la bomba ni intente trabajar en la misma con las manos mojadas o estando parado sobre un suelo mojado Enchufe la bomba so...

Страница 13: ...cuando saque o cambie el eje del motor saque las escobillas del motor consulte el Procedimiento para cambiar las escobillas Coloque las escobillas en donde no se puedan perder o da ar mientras usted c...

Страница 14: ...o del motor de los pliegues tan cerca de los conectores como sea posible es decir deje todo el cable que pueda en el motor 4 Pele todos los cables hasta unos 5 8 del extremo de los mismos AVISO Haga l...

Страница 15: ...s 15 5602 0407 Paso 1 IN IN OUT OUT 5604 0407 IN IN OUT OUT A B IN OUT IN OUT IN OUT IN OUT Paso 2 IN IN OUT OUT 5604 0407 IN IN OUT OUT IN OUT IN OUT IN OUT IN OUT A B Paso 6 5605 0407 IN OUT Paso 3...

Страница 16: ...olsillos de aire o p rdidas en la tuber a de aspiraci n Revisar la tuber a de aspiraci n Impulsor obstruido Sacar y limpiar La bomba se desceba P rdida de aire en la tuber a de aspiraci n Revisar la t...

Страница 17: ...ios de ferreter a 1 C54 30 7 Cord n el ctrico 1 PS17 1507 8 Juego de escobillas Incluye 1 par de escobillas con resortes y casquetes de retenci n 1 FPPKG 226 P2 9 Motor 1 Si la Unidad de la bomba o el...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: